This manual explains how to safely assemble and operate the DW-095IV high pressure cleaner. It includes safety warnings, a parts list, and detailed instructions for connecting hoses, the lance, and the detergent tank.
The guide also covers routine care, winter storage procedures, and a problem‑solving section that helps diagnose common issues such as plug problems, fuse failures, and pump overheating.
| Voltage | 230V~240V/50Hz |
|---|---|
| Rated Pressure | 100bar |
| Maximum Pressure | 150bar |
| Maximum Flow | 6.5L/min |
| Motor Type | Induction |
Wear safety equipment, keep people at least 10 m away, never point the gun at people or live electrical equipment, and use a waterproof extension cord if needed.
Release the water pressure, disconnect the garden hose and power, fill the unit with a 50/50 water‑antifreeze mix, run the pump to circulate the solution, then disconnect hoses and store the unit above 0 °C.
Check that the plug is connected, try a different socket, verify the fuse, ensure the main voltage matches the specification, and reset any RCD that may have tripped.