YBLX-KLT2 series of limit switches are used to protect the tape conveyor from emergency accidents. When an emergency occurs, the switch can be started at any place on the site to send out a stop signal.
This manual describes the YBLX KLT2 series stroke switch, including its intended use for safety shutdown in emergency situations and compliance with GB 14048.5 and IEC 60947-5-1 standards.
It lists the main electrical parameters, mechanical life data, environmental limits, and physical dimensions required for proper installation and ordering of the device. This manual is written in Chinese.
| Maximum altitude | 2000 m |
|---|---|
| Operating temperature range | -25 °C to +40 °C |
It complies with GB 14048.5 and IEC 60947‑5‑1.
The device can operate up to 2000 m altitude.
It operates from –25 °C to +40 °C.