This document is the user manual for the SMS controller SC_001E, compatible with Siemens C25/2588/3508/3518/3568/3618/6618/6688/6686i and other models. The document provides detailed instructions for the initial operation of the SMS controller, including inserting the data cable, setting the authorized phone numbers, and modifying the password. It also describes the method of setting using the upper computer software and lists the supported SMS commands of the controller.
The manual explains how to connect the SC 001E controller to a compatible Siemens mobile phone, power it with the supplied DC supply, and verify successful communication via LED indicators. It then details the process of registering up to four authorized phone numbers by sending specific SMS commands and how to modify the wireless password.
Further sections describe the relay output wiring, software configuration via a PC, the full list of SMS commands for controlling the four relay channels, and the alarm behavior when a short circuit is detected while the system is armed. This manual is written in Chinese.
| Supported Siemens phone models | cz25, 2588, 3508, 3518, 3568, 3618, 6618, 6688, 6686i |
|---|---|
| Maximum authorized phones | 4 |
| Relay output configuration | First relay: NO, COM, NC terminals; other relays driven by PO_1, P0_2, P0_3 |
Send an SMS in the format “旧密码 A 新密码” (e.g., “饮冰入杭州”) to the Siemens phone; the phone will reply confirming the password change.
When the system is armed (AN2 button pressed), any short‑circuit on the six input lines triggers an SMS alarm to the registered numbers; disarming clears the alarm.