Sandpiper S05 Non‑metal Pump Repair Manual

This manual introduces the technical characteristics, performance, structure, installation, start-up and maintenance information of the WARREN RUPP brand S05 type non-metallic 2-level design pneumatic double diaphragm pump.


Sandpiper S05 Non‑metal Pump Repair Manual - cover page
Brand
Sandpiper
Document type
Service Manual
Language
Chinese
Pages
27
File format
PDF
File size
436 KB
Published
27 February, 2012
Updated
30 September, 2023
MD5 checksum
6136931FA6FCA3E7BC303C1826B7D70B

About this manual

This manual provides detailed engineering data, installation steps, and troubleshooting procedures for the Sandpiper S05 non‑metal pneumatic diaphragm pump. It includes specifications, material limits, performance curves, and safety information to ensure proper operation and maintenance.

The document also contains comprehensive parts lists, wiring diagrams, and optional components such as pulse output modules and silencers, helping technicians service the pump and adapt it for special applications like hazardous‑liquid handling. This manual is written in Chinese.

What's inside

  • Engineering Data and Temperature Limits
  • Performance Curves
  • Dimensions (Imperial and Metric)
  • Pump Operation Principle
  • Installation and Startup Guide
  • Air Source and Valve Requirements
  • Troubleshooting and FAQ
  • Parts List and Repair Drawings
  • Safety and Warranty Information

Specifications

Flow rate0‑14 gal/min (0‑52 L/min)
Inlet/Outlet pipe size1/2" NPT (inner) or 1/2" BSPT (tapered) for inlet; 1" NPT (inner) or 1" BSPT (tapered) for outlet
Maximum air source pressure125 psi (8.6 bar)
Maximum head100 psi (≈231 ft water column)

Frequently asked questions

Why does the pump not circulate fluid?

Check the inlet height; if it exceeds 20 ft (6 m) the pump may need to be filled with liquid to start, and ensure a back‑pressure device is installed for high suction heights.

How can pump vibration be reduced?

Install a Warren Rupp Tranquilizer dampener between the pump and rigid piping to lower vibration.

What air pressure is required for operation?

The air source pressure must not exceed 125 psi (8.6 bar).