This document is a maintenance manual for the INAX brand PK-50-1001-2,50-1001-2 product, which mainly introduces the maintenance method of the product
The manual explains how to safely replace the diaphragm packing of the ball tap for the INAX PK-50-1001-2 model. It includes safety notes, detailed removal and installation steps, and verification procedures to ensure proper operation and no water leaks.
Contact information for customer support and repair requests is also provided, allowing users to obtain further assistance or schedule maintenance if needed. This manual is written in Japanese.
| Part number | PK-50-1001-2 |
|---|---|
| Diaphragm packing material | Resin |
After reassembly, operate the tap to confirm normal function and verify that there are no water leaks or other defects.