SAS816WHB-0 is a non-programmable temperature controller that is mainly used for wall-hung boiler water heating control system to control the opening and closing of wall-hung boilers, circulating water pumps or electric actuators to achieve comfortable temperature control.
The SAS816WHB-0 heating temperature controller is designed for wall‑mounted boiler water‑heating systems, controlling the boiler, circulation pump, or electric actuator to maintain comfortable indoor temperatures. The manual explains the device’s keypad, LCD display, dip‑switch configuration, and safety precautions for installation and maintenance.
Key functions include temperature setting via a rotary dial, mode selection between heating and cooling, battery‑low and sensor‑fault alarms, and optional energy‑saving operation. Detailed wiring diagrams and dip‑switch settings allow installers to customize temperature units, protection features, and operating modes. This manual is written in Chinese.
| Working voltage | 2 AA dry cells |
|---|---|
| Power consumption | 0.2 mW |
| Relay output | 250 VAC 10 A |
| Temperature accuracy | ±1 °C (approx.) |
| Temperature control range | –30 °C to 86 °C |
| Operating ambient temperature | 0 °C to +50 °C (32 °F–122 °F) |
| Storage temperature range | -10 °C to +60 °C (14 °F–140 °F) |
| Dimensions | 86 × 86 × 32 mm |
Turn the rotary temperature dial while the unit is powered on; the LCD will flash and show the set temperature, then return to displaying the room temperature after 5 seconds.
Use dip‑switch 4 to select heating or cooling; the LCD will indicate the active mode with the corresponding icon.
When the battery‑low icon (6) is steady, the battery is low but the controller still works; if it flashes, the battery is critically low and the controller shuts off until the battery is replaced.
A short‑circuit on the sensor causes the display to show “EL” and the controller stops output; an open‑circuit shows “权” and also stops output.