This document provides instructions and features of the Microcomputer Temperature Controller (STC-200), including temperature control, alarm output, cooling and heating modes.
This manual describes how to use the STC-200 microcomputer thermostat, including user and manager menus, parameter adjustments, and the various operating modes such as cooling, heating, and alarm output. It also details the alarm functions for sensor faults and out‑of‑range temperatures.
Installation requirements, wiring diagrams, and technical specifications are provided to ensure proper setup. The document includes guidance on power supply, humidity limits, and safe connection of sensor, power, and relay leads. This manual is written in Chinese.
| Overall dimensions | 77.0×34.5×65.5 mm |
|---|---|
| Installation hole size | 70.5×28.5 mm |
| Operating temperature range | -5 °C to 60 °C |
| Storage temperature range | -30 °C to 85 °C |
| Relative humidity | 20 % to 60 % (no condensation) |
| Power supply voltage | 220 VAC ±10 % (12 V ±10 % optional) |
| Power consumption | < 5 W |
| Temperature measurement range | -40 °C to 99 °C |
| Control temperature range | -40 °C to 70 °C |
| Resolution | 1 unit |
| Temperature control accuracy | ±1 °C |
| Relay contact capacity | 7 A / 250 VAC / 30 VDC |
Press the SET key for more than 5 seconds or wait 30 seconds without any key operation; the system saves the set temperature and returns to normal operation.
E1 indicates a sensor open‑circuit fault; the LED flashes “E1” and the buzzer sounds.
The thermostat can be powered from 220 VAC ±10 % or optionally from 12 V ±10 %.
In user setting mode, press the ▲ or ▼ keys to increase or decrease the temperature by 1 °C per press; hold the key for more than 2 seconds for rapid adjustment.