This is a static electricity removal unit, which uses the high frequency AC method to alternately release positive and negative ions to achieve accurate static electricity removal.
About this manual
This manual covers safety precautions, installation steps, and proper use of the Koganei static electricity removing unit. It explains the different ionizer types (blow, fan, air‑gun), nozzle options, and maintenance requirements.
Detailed sections describe the low‑particle blow type, compact blow type, nozzle configurations, application examples, and technical specifications such as weight, voltage, and performance characteristics.
What's inside
- Safety Precautions
- Installation
- Precautions on Use
- Blow Type
- Compact Blow Type
- Nozzles for Blow Type
- Application Examples
- Specifications
Specifications
| Weight (Air Gun type) | 140 g |
|---|
| Minimum nozzle distance | 1 mm |
|---|
| Decay time (1000 V → 100 V, 100 mm) | within 1 second |
|---|
| Size/weight reduction (compact blow type) | 30 % volume, 35 % weight |
Frequently asked questions
What must be done before cleaning or maintenance?
Always shut off the power supply before inspecting, cleaning, or performing maintenance.
What media should be used with the Blow Type unit?
Only clean air should be used; other media are not permitted.
Can the unit be used near flammable substances?
No, the product must not be used in locations with or near flammable or ignitable substances.