This manual introduces the features and characteristics of Fluke 80 series V multimeters, including warranty information, function introduction, power on function options, automatic power off, Input Alert™ function, measuring AC and DC voltage, True RMS multimeter zero input characteristic, low pass filter, temperature measurement, connectivity testing, resistance measurement, high resistance or leakage measurement using conductivity principle
The Fluke 80 Series V multimeter manual provides comprehensive safety instructions, functional overviews, and detailed measurement procedures for voltage, current, resistance, capacitance, frequency, duty cycle, and pulse width. It also includes guidance on maintenance, battery and fuse replacement, and part replacement.
Technical specifications such as accuracy, input impedance, frequency range, and detailed functional limits are listed in tabular form, along with warranty information and contact details for Fluke service centers worldwide. This manual is written in Chinese.
| Frequency measurement range | 1 kHz – 2.5 kHz |
|---|
You can register the product online at www.fluke.com or directly at register.fluke.com.
The XW warning indicates a situation or behavior that could cause danger to the user.