SUNX FX-100 Digital Optical Fiber Sensor Product Leaflet

This document describes the features and characteristics of the FX-100 series digital fiber optic sensors, including manual and digital settings, analog output, leak/liquid level detection, easy wiring, and storage selection components. The series of sensors have universal connectors, reducing deployment time and maintenance costs.


SUNX FX-100 Digital Optical Fiber Sensor Product Leaflet - cover page
Brand
NEW
Category
Other Electronics
Document type
Product Leaflet
Language
Chinese
Pages
20
File format
PDF
File size
5.8 MB
Updated
28 September, 2023
MD5 checksum
57F6FFFCA54A3EA979A4C5D3FB2158CB

About this manual

The SUNX FX-100 series is a digital optical fiber sensor amplifier with two digital displays that let users check the reference value and incident light level at the same time. It supports manual setting, digital setting, teaching, and RUN/SET/PRO operating modes, and is offered in standard and long-distance types with NPN or PNP open-collector outputs.

The ordering guide lists models such as FX-101, FX-101P, FX-102 and FX-102P, including connector (M8) and cable-assembly variants. Specifications include a 12–24 V DC supply, response times from 250 μs, a 4-digit green plus 4-digit red LCD display, and an ambient temperature range of -10 to +55 °C. I/O circuit and wiring diagrams are provided for NPN and PNP output types. This manual is written in Chinese.

What's inside

  • Ordering Guide
  • Specifications
  • I/O Circuit and Wiring Diagrams
  • Manual Setting
  • Digital Setting
  • Analog Output
  • Liquid Leak/Level Detection
  • Simple Wiring
  • Other Products

Specifications

Supply voltage12–24 V DC ±10%
Power consumption (normal)720 mW or less
NPN output max sink current100 mA
Response time250 μs or less (frequency 0)
Digital display4-digit green + 4-digit red LCD
Ambient temperature-10 to +55 °C
Main unit weightapprox. 15 g
Light emitting elementred LED

Frequently asked questions

What is the power supply voltage?

12 to 24 V DC ±10% with ripple of 10% or less.

Can settings be copied from one amplifier to another?

Yes, the setting copy function copies the master amplifier's settings to the slave amplifier.

What is the response time at light emission frequency 0?

250 μs or less (factory setting).

Download PDF (5.8 MB)