Emerson Motion Control EN-208 Digital Servo Drive Installation Manual
This is the Installation Manual (P/N 400501-02, Revision A5, dated January 10, 2003) for the EN series of digital servo drives from Control Techniques, an Emerson Electric company. The manual addresses the EN-204, EN-208 and EN-214 drives, with the EN-208 rated at 9 A RMS continuous and 18 A peak output current. It opens with customer support contacts, document conventions and general safety instructions for qualified persons.
The manual also covers UL listing conditions of acceptability, drive overload protection, reference materials for related modules and cables, and technical sections such as IP ratings, encoder specifications, power dissipation, speed torque curves, EN drive and MG/NT motor dimensions, motor wiring color cable and cable diagrams, followed by a glossary and index. The copy supplied here carries an Artisan Technology Group reseller cover page describing it as used equipment.
Covers: Safety Instructions · Customer Support · Reference Materials · Underwriters Laboratories Listed · Drive Overload Protection · IP Ratings
Latest Emerson Motion Control manuals
Emerson Motion Control EN-208 Digital Servo Drive Installation Manual
Installation Guide 110 pages · 24.6 MB · ENInstallation manual for the Emerson Motion Control EN-208 digital servo drive, covering safety instructions, drive overload protection, specifications and…
Which document do I need?
Installation Guide
Mounting, wiring and first power-up. Read it before the hardware goes in.
Questions answered in Emerson Motion Control manuals
What is the continuous and peak output current of the EN-208 drive?
The EN-208 has a continuous rating of 9 A RMS and a peak rating of 18 A.
From: Emerson Motion Control EN-208 Digital Servo Drive Installation Manual
What ambient temperature does the drive require for a UL-listed installation?
The surrounding air ambient temperature must be 40 °C (104 °F) or less; operation up to 50 °C (122 °F) is allowed with 3% linear derating for every degree above 40 °C.
From: Emerson Motion Control EN-208 Digital Servo Drive Installation Manual