Max-Gain Systems PL-259 Connector Installation Guide
This guide provides step-by-step instructions for installing a PL-259 UHF male connector on coaxial cables such as RG-174, RG-316, LMR-100A, and other 0.100-inch OD cables using a UG-174 reducer. It covers cable stripping dimensions, reducer placement, main body threading, center conductor preparation, soldering the center pin and four body holes, and final resistance testing.
The document includes a FAQ addressing a bent center conductor and emphasizes cleaning the soldering iron tip, heating the pin from the bottom, and verifying infinite resistance between center pin and body after assembly. A final visual inspection for excess solder on the center pin tip is recommended.
Covers: Compatible Cables · Coax Stripping · Reducer Installation · Main Body Install · Soldering Guide · FAQ
Latest Max-Gain Systems manuals
Max-Gain Systems PL-259 Connector Installation Guide
Installation Guide 3 pages · 258 KB · ENInstallation and soldering guide for Max-Gain Systems PL-259 UHF male quick-connect solder-on connector with UG-174 reducer.
Which document do I need?
Installation Guide
Mounting, wiring and first power-up. Read it before the hardware goes in.
Questions answered in Max-Gain Systems manuals
Why won't the center conductor go into the connector?
The center conductor is bent off center; ensure it is perfectly straight before screwing the connector body onto the coax.
How do you test the connector after installation?
Check resistance from the center pin to the body with an ohmmeter on a low resistance scale; you should see infinite resistance (open) if there are no braid-to-center-pin shorts.