Datasheet

Ratings, dimensions and ordering codes, for selection and design work.

Questions answered in Dresser Masoneilan manuals

What is the standard seat leakage class for the 21000 Series?

The standard tight shutoff is Class IV leakage.

From: Dresser Masoneilan 21000 Series Control Valves Specification Data

Is the 21000 Series suitable for sour service applications?

Yes, it is available for Sour Service Applications using NACE Standard MR 0103.

From: Dresser Masoneilan 21000 Series Control Valves Specification Data

What is the body pressure rating?

The standard body pressure rating is ANSI Class 600 per B16.34. For flanged construction, the valve rating is limited by the flange rating.

From: Dresser Masoneilan Camflex II 35002 Series Rotary Control Valves Specification Data

What fluid temperature range does the standard integral extension bonnet allow?

It allows a range of -320°F to 750°F (-196°C to 400°C).