Key facts
- Manuals
- 1
- Languages
- PT
- Last added
- 2023-11-16
Featured TecnoMarc manuals

TecnoMarc TM-01 Benchtop Electropneumatic Dater User Manual
This is the Portuguese user manual for the TecnoMarc TM-01 benchtop electropneumatic dater, a machine that stamps text onto packaging using nitrile rubber clichés and an ink cartridge. It walks the user through the first procedures: selecting the 110 or 220 V voltage on the base, connecting the 6 mm compressed-air hose to the compressor, and setting the regulator to 4 bar (60 lbs).
The manual then explains how to start production, including mounting the cliché holder horizontally or vertically, adjusting the print head height with the upper handle and the lateral handles, leveling with the three adjusting screws, and running the machine with the electric pedal or in automatic mode. It also covers air flow regulating valves, the internal parts of the cartridge, first inking and refilling, reactivating dried ink with SV-01 cleaning solution, cleaning the clichés, consumables, optional accessories, and technical characteristics. This manual is written in Portuguese.
Covers: Primeiros procedimentos para utilização do datador · Iniciando a produção · Regulagens do fluxo de ar · Descritivo interno do cartucho · Primeira entintação e reabastecimento do cartucho · Reativação da tinta no cartucho
Latest TecnoMarc manuals
TecnoMarc TM-01 Benchtop Electropneumatic Dater User Manual
User Manual 12 pages · 698 KB · PTTecnoMarc TM-01 benchtop electropneumatic dater user manual: setup, air flow adjustment, inking and cleaning the cartridge, consumables and specifications.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in TecnoMarc manuals
What air pressure should the TM-01 be set to?
Set the regulator to a pressure of 4 bar or 60 lbs when letting compressed air flow.
From: TecnoMarc TM-01 Benchtop Electropneumatic Dater User Manual
How much ink is used for the first inking of the cartridge?
Use approximately 80 ml of well-shaken ink, added through the rear cap with the 100 ml dosing bottle.
From: TecnoMarc TM-01 Benchtop Electropneumatic Dater User Manual