Vontron ULP Series Ultra Low Pressure Membrane Element Product Manual
The Vontron ULP Series is a line of ultra-low pressure aromatic polyamide compound membrane elements developed by Vontron Technology Co., Ltd. The elements are intended for desalination of surface water and underground water and operate at approximately two thirds of the operating pressure of regular low-pressure composite membrane, with a salt rejection rate of up to 99.5%.
The document gives testing conditions, operation limits and conditions, model-specific active membrane area, average permeated flow and rejection rates, dimensions of the membrane element, and important handling and storage information.
Covers: Brief Introduction · Specifications and Major Properties · Testing Conditions · Operation limits and conditions · Dimensions of Membrane Element · Important Information
Latest Vontron manuals
Vontron ULP Series Ultra Low Pressure Membrane Element Product Manual
Product Leaflet 4 pages · 424 KB · ENVontron ULP Series ultra-low pressure aromatic polyamide membrane elements for desalination, with specifications and operating limits.
Questions answered in Vontron manuals
What is the maximum working pressure of a ULP Series element?
The maximum working pressure is 600 psi (4.14 Mpa).
From: Vontron ULP Series Ultra Low Pressure Membrane Element Product Manual
What is the maximum feedwater temperature?
The maximum feedwater temperature is 45 ℃.
From: Vontron ULP Series Ultra Low Pressure Membrane Element Product Manual