Featured 威科达 manuals

Weikeda VEC-VA VECTOR Motion Controller User Manual
This is the Chinese user manual for the Weikeda (深圳威科达科技有限公司) VEC-VA series VECTOR motion controller. It begins with the unpacking checklist and packing list, explains the model designation code VEC-VA-MM-XXX-Y, and lists the storage environment (-20 °C to +65 °C, 0% to 95% RH) and operating environment (-10 °C to +40 °C). Safety, design, wiring, start-up, maintenance and disposal precautions are given, followed by DIN-rail mounting, removal and placement instructions.
The product chapter describes a controller built around ARM and FPGA with five axis interfaces (one spindle and four servo axes expandable to 64), a servo control period under 1 ms and programming with the KW-Multiprog tool supporting IEC 61131-3 languages. The remaining chapters define the terminals — digital I/O, RS-232 (COM1) and RS-485, the 24 V system and digital I/O supplies, axis interfaces and analog inputs/outputs — and give wiring diagrams for connecting Weikeda, Delta, Mitsubishi, Fuji, Panasonic and Yaskawa servo drives, plus mounting dimensions and an expansion module overview. This manual is written in Chinese.
Covers: Unpacking check and packing list · Model designation · Storage and operating environment · Safety and wiring precautions · Mounting and removal · Motion controller introduction
Latest 威科达 manuals
Weikeda VEC-VA VECTOR Motion Controller User Manual
User Manual 26 pages · 1.2 MB · ZHWeikeda VEC-VA VECTOR motion controller user manual: unpacking checks, storage and use conditions, installation, terminal definitions and servo drive wiring.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in 威科达 manuals
How many axes does the Weikeda VEC-VA motion controller support?
It has five axis interfaces consisting of one spindle interface and four servo axis interfaces, and the servo axes can be expanded to 64.
What ambient temperature range does the controller require?
The operating environment temperature is -10 °C to +40 °C; for long-term operation a temperature below +40 °C is recommended.