861DW SMD Rework System Instruction Manual
This manual provides instructions for operating the 861DW SMD rework system, including safety precautions, temperature and airflow settings, channel selection, and calibration procedures. It also details how to replace parts like the heating element and nozzle, and explains the unit's automatic sleep and cooling functions. The system is designed for reworking and soldering SMD components with adjustable temperature and airflow settings.
Covers: Safety Instruction · Characteristic · Assembly and Change of the Nozzle · Calibration · Replacing the Parts · Setting of the Temperature and the Airflow
Latest 861DW SMD REWORK SYSTEM manuals
861DW SMD Rework System Instruction Manual
User Manual 14 pages · 578 KB · ENInstruction manual for the 861DW SMD rework system, covering safety, operation, calibration, and maintenance.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in 861DW SMD REWORK SYSTEM manuals
How does the unit enter sleep mode?
Place the handle on the holder; the unit automatically enters sleep mode when temperature cools below 100°C.
How do I calibrate the temperature?
Set the calibration temperature to 300°C, test the outlet temperature with a thermometer, then enter calibration mode by pressing "CH1" and "CH3" keys simultaneously for 15 seconds.