Wanhua Jieneng Keji B2 Grade Polyurethane Spray Foam Insulation Technical Data Sheet
This technical data sheet (TDS no. WHF_203, version V1.0, revised 2021-06-01) from Wanhua Jieneng Keji (Yantai) Co., Ltd. describes a B2 grade polyurethane rigid foam spray insulation blend for building exterior walls. The blowing agent is described as an environmentally friendly agent with very low thermal conductivity, and the blend is used together with WANNATE®2208 on cement, brick, wood and other substrates. It is a fast-curing system that can bear load immediately, and its burning behavior is rated B2 according to GB8624-2012. Typical uses are spray insulation of cold storage, food plants, chemical plants, industrial and civil buildings, pipes and tanks.
The sheet lists viscosity, density, free-foam reaction times, foam density, thermal conductivity, compressive strength, dimensional stability, closed-cell ratio and water absorption. Application notes cover high-pressure spray equipment, a 1:1 material volume ratio, ambient temperature of 10~40°C, wind speed no more than 5 m/s and relative humidity below 75%, plus fire precautions and the requirement to carry out a trial before full-scale work. It also gives packaging (200 L green steel drum), storage between 5 and 35°C in sealed containers, a 6-month shelf life, and safety, fire, spill and contact information. This manual is written in Chinese.
Covers: Product Introduction · Product Applications · Physical and Chemical Properties · Free Foam Parameters · Physical Properties · Application Notes
Latest 万华节能科技 manuals
Wanhua Jieneng Keji B2 Grade Polyurethane Spray Foam Insulation Technical Data Sheet
Datasheet 4 pages · 850 KB · ZHTechnical data sheet for Wanhua Jieneng Keji B2 grade polyurethane rigid spray foam insulation, listing physical properties, application notes, storage and…
Which document do I need?
Datasheet
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in 万华节能科技 manuals
What ambient conditions are recommended for spraying?
The ambient temperature should be 10~40°C, wind speed no more than 5 m/s (level 3 wind) and relative humidity below 75%; do not apply in rain.
From: Wanhua Jieneng Keji B2 Grade Polyurethane Spray Foam Insulation Technical Data Sheet
What is the mixing ratio and material temperature for manual foaming?
The material temperature is 25°C and the volume ratio of the two components is 1:1, mixed by hand with an electric stirrer at 2500 r/min.