Feilo Sylvania LED Sensor Tube Installation Guide
This guide provides safety precautions and installation steps for Feilo Sylvania LED sensor tubes. It specifies that only qualified personnel should install the tubes and outlines compatibility requirements, such as not using them with pilot light switches or dimmers. The guide also includes installation diagrams for single and dual tube setups and notes the operating temperature range of -10°C to +40°C.
The document warns against direct viewing of the tube when lit, applying paint or coatings, and disassembling the tube to replace parts. It also specifies that the tube is for indoor use only and must be installed in G13 sockets meeting IEC standards. The detection range is 5 meters, with light output reducing to 10% when no motion is detected for 3 minutes. This manual is written in Spanish.
Covers: Safety Precautions · Installation Requirements · Mounting Diagrams · Operating Temperature · Detection Range · Compatibility

Feilo Sylvania LED Panel SP Installation Guide
This guide provides safety instructions and step-by-step installation procedures for the Feilo Sylvania LED Panel SP. It emphasizes disconnecting power before installation, using professional electricians, ensuring proper ventilation, and avoiding modifications that void warranty. Installation steps include marking screw points, securing the mounting frame, connecting wires correctly, and energizing the unit. The guide also specifies compatible mounting locations and warns against using dimmers or sensors not designed for this product.
Maintenance instructions advise cleaning every six months with a soft cloth and mild soap, avoiding chemicals or abrasive materials, and ensuring no obstructions near the unit for proper airflow. This manual is written in Spanish.
Covers: Safety Precautions · Installation Steps · Maintenance and Cleaning · Compatibility and Restrictions · Wiring Instructions

Feilo Sylvania UV-C Desktop Sterilizer Lamp Installation and Operation Manual
The Feilo Sylvania UV-C sterilizer lamp is designed to generate ultraviolet light within the UV-C wavelength range to destroy microorganisms such as viruses, bacteria, and fungi by deactivating their DNA. It is intended for indoor use only and is not suitable for humid, flammable, explosive, or dusty environments. This manual is written in Spanish.
Covers: Medidas de Seguridad · Función · Instalación y Funcionamiento · Precaución · Limpieza y Mantenimiento

Feilo Sylvania UV PRO UV-C Lamp User Manual
This manual provides safety guidelines and operational instructions for the Feilo Sylvania UV PRO UV-C germicidal lamp. It details how to install, operate, and maintain the lamp safely, including precautions for use in enclosed spaces and warnings against direct exposure. The lamp is designed to disinfect areas using UV-C light, with recommended exposure times based on room size. Maintenance includes monthly cleaning and replacing the lamp after 8000 hours of use. This manual is written in Spanish.
Covers: Safety Measures · Installation · Operation · Precautions · Cleaning and Maintenance · Warranty and Disposal
Latest Feilo Sylvania manuals
Feilo Sylvania LED Sensor Tube Installation Guide
Installation Guide 1 pages · 334 KB · ESInstallation instructions for Feilo Sylvania LED sensor tubes, including safety warnings and mounting guidelines.
Feilo Sylvania LED Panel SP Installation Guide
Installation Guide 2 pages · 436 KB · ESInstallation guide for Feilo Sylvania LED Panel SP with safety precautions and step-by-step mounting instructions.
Feilo Sylvania UV-C Desktop Sterilizer Lamp Installation and Operation Manual
User Manual 1 pages · 161 KB · ESThis manual provides installation, operation, and safety instructions for the Feilo Sylvania UV-C desktop sterilizer lamp.
Feilo Sylvania UV PRO UV-C Lamp User Manual
User Manual 1 pages · 174 KB · ESUser manual for Feilo Sylvania UV PRO UV-C germicidal lamp with safety, installation, and maintenance instructions.
Which document do I need?
Installation Guide
Mounting, wiring and first power-up. Read it before the hardware goes in.
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in Feilo Sylvania manuals
Can I install this LED sensor tube myself?
No, the tube must be installed by qualified personnel.
What is the detection range of the sensor?
The detection range is 5 meters.
What safety precautions should be taken during installation?
Disconnect power before installation, use a professional electrician, ensure proper ventilation, avoid covering the unit, and do not modify or disassemble it.
How should the LED Panel SP be cleaned?
Clean every six months with a soft, lint-free cloth and mild soap, then dry with a clean dry cloth. Avoid chemicals, alcohol, gasoline, or insecticides.
How long should I sterilize an area of 10 m²?
For an area of 10 m², the sterilization time is 15 minutes.
From: Feilo Sylvania UV-C Desktop Sterilizer Lamp Installation and Operation Manual
What should I do after disinfection?
Open the window and ventilate for about 30 minutes before entering the area.
From: Feilo Sylvania UV-C Desktop Sterilizer Lamp Installation and Operation Manual