Solis BioDyne 5x HOT FIREPol Probe Universal qPCR Mix Kit Product Testing Manual
The document is a product testing manual for the 5x HOT FIREPol® Probe Universal qPCR Mix (Catalog No. VIAL SIZE 08-17-0000S) manufactured by Solis BioDyne. It details instrument compatibility, noting that the mix contains a reference dye based on ROX suitable for platforms from Applied Biosystems and Stratagene, but does not support Fast Mode thermal cycling conditions.
The manual outlines specific preparation protocols, including thawing at room temperature and preparing reaction master mixes to minimize pipetting errors. It specifies recommended cycling parameters, such as an initial activation step of 10 minutes at 95°C, and provides a table for optimizing DMSO concentrations based on template GC content.
Covers: Contents · Instrument Compatibility · Important notes · Description · Protocol · Reaction master mix
Latest Solis BioDyne manuals
Solis BioDyne 5x HOT FIREPol Probe Universal qPCR Mix Kit Product Testing Manual
Product Leaflet 4 pages · 890 KB · ENThis manual provides testing, storage, and usage instructions for the Solis BioDyne 5x HOT FIREPol Probe Universal qPCR Mix Kit.
Questions answered in Solis BioDyne manuals
What initial step is required to activate the DNA polymerase before starting the PCR cycle?
You must include an incubation step at 95°C for 10 minutes at the beginning of the qPCR cycle to activate the polymerase.
From: Solis BioDyne 5x HOT FIREPol Probe Universal qPCR Mix Kit Product Testing Manual
What is the recommended maximum concentration of DMSO for templates with high GC content?
The highest recommended DMSO concentration is 10%, which should be used for all templates with GC content over 70%.
From: Solis BioDyne 5x HOT FIREPol Probe Universal qPCR Mix Kit Product Testing Manual