TBI MOTION A72TBI Linear Guide Rail Length and Mounting Guide
TBI MOTION offers standard and customized rail lengths for the A72TBI International Standard Linear Guide. To ensure stable running performance, the document specifies that the end cap value G should not exceed half the distance between mounting holes (F) when ordering customized lengths. It provides the formula L = [n-1] F + 2G to calculate the total length, where n is the number of mounting holes.
Covers: Rail Length Calculation · Mounting Hole Specifications · Top Mounting Type · Bottom Mounting Type · Rail Size Chart
Latest TBI MOTION manuals
TBI MOTION A72TBI Linear Guide Rail Length and Mounting Guide
Product Leaflet 2 pages · 249 KB · ENThis document provides formulas and charts for calculating total rail length and mounting hole specifications for TBI MOTION A72TBI linear guides.
Questions answered in TBI MOTION manuals
How do I calculate the total length of a customized rail?
Use the formula L = [n-1] F + 2G, where L is the total length, n is the number of mounting holes, F is the distance between holes, and G is the distance from the last hole to the edge.
From: TBI MOTION A72TBI Linear Guide Rail Length and Mounting Guide
What is the maximum value for the end cap G?
TBI suggests that the end cap value G should be no greater than 1/2F to prevent unstable running performance.