Featured Huace Chuangshi manuals

Huace Chuangshi 9011 Vibration String Rebar Stress Gauge Installation and Use Manual
The document provides instructions for the Huace Chuangshi 9011 Vibration String Rebar Stress Gauge. It explains that the device measures strain in embedded steel bars by detecting changes in the resonant frequency of a vibrating wire, allowing engineers to monitor stress in structures like piles and bridge piers.
Detailed guidance is provided on installation procedures, including initial inspection checks for cable resistance and insulation. The manual covers specific installation methods such as welding the gauge directly to rebar or using sister bars, along with instructions for extending cables using heat-shrink connectors. This manual is written in Chinese.
Covers: Introduction · Technical Parameters · Initial Inspection · Cable Extension Welding · Rebar Gauge Installation · Sister Bar Installation

Huace Chuangshi GNSS Integrated Unit Fiber Bragg Grating Demodulator User Manual
This manual describes the usage of the Huace Chuangshi Fiber Bragg Grating Demodulator, a portable instrument utilizing scanning laser technology for high-precision measurement of physical quantities such as temperature, strain, and pressure. The device is designed for field testing in engineering applications including bridges, tunnels, and power grids. This manual is written in Chinese.
Covers: Overview · Safety and Compatibility · Hardware Operation · Software Operation · Sensor Configuration · System Settings

Huace Chuangshi HC-FBGYL60 Fiber Bragg Grating Soil Pressure Gauge User Manual
The document provides a user guide for the HC-FBGYL60 Fiber Bragg Grating Soil Pressure Gauge manufactured by Shanghai Huace Chuangshi Measurement and Control Technology Co., Ltd. It details the product's operating principle based on wavelength changes in optical fibers when subjected to stress, highlighting advantages such as stability and anti-electromagnetic interference capabilities.
The guide includes instructions for installation steps, including initial inspection and specific requirements for backfilling materials to ensure accurate pressure readings. It also explains how to read data using a demodulator and provides the calculation equation for converting wavelength shifts into soil pressure values. This manual is written in Chinese.
Covers: Product Introduction · Main Technical Parameters · Installation Steps · Fiber Optic Connection · Data Reading and Processing
Latest Huace Chuangshi manuals
Huace Chuangshi 9011 Vibration String Rebar Stress Gauge Installation and Use Manual
User Manual 12 pages · 1.5 MB · ZHThis manual covers the installation, operation, and troubleshooting of the Huace Chuangshi 9011 vibration string rebar stress gauge for measuring steel…
Huace Chuangshi GNSS Integrated Unit Fiber Bragg Grating Demodulator User Manual
User Manual 13 pages · 2.4 MB · ZHUser manual for the Huace Chuangshi GNSS Integrated Unit Fiber Bragg Grating Demodulator, covering hardware operation, software settings, and sensor…
Huace Chuangshi HC-FBGYL60 Fiber Bragg Grating Soil Pressure Gauge User Manual
User Manual 12 pages · 696 KB · ZHThis manual covers the installation, operation, and data processing for the Huace Chuangshi HC-FBGYL60 fiber optic soil pressure gauge.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in Huace Chuangshi manuals
What is the recommended welding method for the 9011 gauge?
The manual recommends using groove welding (坡口焊接) as the preferred welding technique.
From: Huace Chuangshi 9011 Vibration String Rebar Stress Gauge Installation and Use Manual
How should cables be extended if needed during installation?
Cables should be extended by welding, ensuring shielded twisted cable is used and connections are waterproof with heat-shrink or epoxy joints.
From: Huace Chuangshi 9011 Vibration String Rebar Stress Gauge Installation and Use Manual
What is the operating voltage of the demodulator?
The instrument uses 220VAC or +12VDC power.
From: Huace Chuangshi GNSS Integrated Unit Fiber Bragg Grating Demodulator User Manual
How long can the device operate on a full charge?
It can continuously collect data for about 5 hours under full load.
From: Huace Chuangshi GNSS Integrated Unit Fiber Bragg Grating Demodulator User Manual
What is the minimum grain size required for backfilling around the sensor?
Particles larger than 10mm must be removed from the material surrounding the pressure box to prevent local deformation.
From: Huace Chuangshi HC-FBGYL60 Fiber Bragg Grating Soil Pressure Gauge User Manual
When should initial wavelength readings be collected after installation?
It is recommended to collect initial wavelength readings 2-3 days after installation due to the creep process of the sensor.
From: Huace Chuangshi HC-FBGYL60 Fiber Bragg Grating Soil Pressure Gauge User Manual