Wright Flow Technologies Frame 6 & 7 Pump Installation, Operation and Maintenance Manual
This manual provides installation, operation, and maintenance instructions for Wright Flow Technologies Revolution Frame 6 & 7 pumps. It covers safety information, pump model designation, general operating principles, system design, start-up and shutdown procedures, and routine maintenance.
Additional sections describe disassembly and assembly, single and double seal arrangements, seal pressure limits, and product specifications including clearances, fasteners, lubricants, materials, weights, foundation dimensions, noise data, tools, and service history.
Covers: Safety Information · Introduction · General · Revolution Disassembly and Assembly · Seal Section · Specifications
Latest Wright Flow Technologies manuals
Wright Flow Technologies Frame 6 & 7 Pump Installation, Operation and Maintenance Manual
User Manual 70 pages · 4.3 MB · ENWright Flow Technologies Revolution Frame 6 & 7 pump manual covering installation, operation, maintenance, safety, disassembly, seals, and specifications.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in Wright Flow Technologies manuals
What condition must the pump and system meet before operation?
The pump and all connected system parts must be clean and free from debris, with all suction and discharge valves fully opened.
From: Wright Flow Technologies Frame 6 & 7 Pump Installation, Operation and Maintenance Manual
What differential pressure is recommended during a CIP cleaning cycle?
A pump differential pressure of between 2 and 3 bar (30 and 45 psi) is recommended.
From: Wright Flow Technologies Frame 6 & 7 Pump Installation, Operation and Maintenance Manual