Which document do I need?

Application Note

How to use the product for one specific task, with worked examples.

Datasheet

Ratings, dimensions and ordering codes, for selection and design work.

Questions answered in QUANTA manuals

What is the default over-voltage protection threshold?

The default OVP threshold is 40V.

From: Quanta CP2120 Boost DC/DC Converter Application Design Guide

How does the SHDN pin control the device state?

The device starts working when the voltage is above 1.4V and enters shutdown mode below 0.4V.

From: Quanta CP2120 Boost DC/DC Converter Application Design Guide

What is the feedback voltage of the CP2121?

The feedback voltage is 1.21V.

From: Quanta CP2121 Boost Converter Datasheet

What is the maximum continuous power dissipation?

The maximum continuous power dissipation is 0.45W at TA=25°C.

From: Quanta CP2121 Boost Converter Datasheet