Key facts
- Manuals
- 5
- Languages
- EN
- Last added
- 2023-10-18
Featured Power Gear manuals

Power Gear 3010001346 Room Slideout System Owners Manual
The Power Gear 3010001346 Room Slideout System is a rack and pinion design operated by a 12 Volt DC electric motor. The system includes inner rail assemblies to support room weight and features a specially designed control with programmable stops for fully extended or retracted positions. It also includes a manual override for operation during a loss of power. The system is designed to require very little maintenance, provided users follow the specified procedures for cleaning and lubrication.
Covers: Introduction · Installation · Operation Mode · Preventative Maintenance · Fault Diagnostics · Troubleshooting

Power Gear FLS/RPE DigiSync Room Slide Operation Manual
This manual provides operating instructions for the Power Gear FLS/RPE DigiSync Room Slide Mechanism, which utilizes a hall effect sensor to synchronize the movement of drive arms for smooth room slide operation. The system consists of one or two drive arms, each moved by a 12 VDC gear motor driven by either a rack and pinion (RPE) or Acme Screw (FLS) mechanism.
Covers: Introduction · Operating Your Room · Slide Fault Diagnostics · Override Modes · RPE Crank Mode · FLS Crank Mode

Power Gear Electric Slide-Out System Operations and Service Manual
This document serves as both an operations and service manual for Power Gear electric slide-out systems. It describes the rack and pinion design, outlines safety warnings, and provides step-by-step instructions for extending and retracting the slide-out room using the electric motor or manual override. The guide emphasizes ensuring the room path is clear and keeping away from rails during operation to prevent injury.
Covers: System Description · How to Operate Your Slideout System · Manually Overriding Your Slideout System · Preventative Maintenance · Service Parts · Replacement Kits

Power Gear cCPowerGear Slideout Systems Operations Manual
The document serves as an operations manual for the Power Gear electric slideout system found in Fleetwood Motorhome units. It details the four major components of the system: inner rail assemblies, a 12 volt DC motor and drive shaft, a manual override system, and a control unit with load sensing capabilities.
Covers: Introduction · System Description · Operating the Slideout System · Overriding the Slideout System · Troubleshooting (Electric Wiring) · Preventative Maintenance
Latest Power Gear manuals
Power Gear 3010001346 Room Slideout System Owners Manual
User Manual 5 pages · 756 KB · ENThis manual covers the installation, operation, maintenance, and troubleshooting of the Power Gear 3010001346 programmable control room slideout system.
Power Gear FLS/RPE DigiSync Room Slide Operation Manual
User Manual 4 pages · 743 KB · ENOperation manual for Power Gear FLS/RPE DigiSync room slide mechanisms, covering usage, diagnostics, and override modes for coach room slideouts.
Power Gear Electric Slide-Out System Operations and Service Manual
Service Manual 110 pages · 3.8 MB · ENThis manual provides operating instructions, preventative maintenance, and detailed service procedures for Power Gear electric slide-out systems.
Power Gear cCPowerGear Slideout Systems Operations Manual
User Manual 4 pages · 372 KB · ENThis manual provides operating instructions, troubleshooting steps, and preventative maintenance guidelines for Power Gear electric slideout systems in…
Power Gear 82-S0010-01 Motorhome Slide-Out Systems Operations Manual
User Manual 11 pages · 375 KB · ENThis manual provides operating instructions, override procedures, electrical wiring information, and maintenance guidelines for Power Gear electric…
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Service Manual
Disassembly, diagnostics and part numbers, for repair.
Questions answered in Power Gear manuals
How do I operate the slideout system if there is a loss of power?
The system is equipped with a manual override that allows you to extend or retract the room in the event of a loss of power.
From: Power Gear 3010001346 Room Slideout System Owners Manual
Where can I find help if I have problems?
You should consult your local authorized dealer if you have any problems or questions.
From: Power Gear 3010001346 Room Slideout System Owners Manual
What is the purpose of the DigiSync system?
It synchronizes the movement of the two arms that support the room to ensure good room slide seals and smooth, even room slide operation.
From: Power Gear FLS/RPE DigiSync Room Slide Operation Manual
How does the system prevent the room from moving during travel?
A motor brake is used on RPE systems, while an acme screw is used on FLS systems.
From: Power Gear FLS/RPE DigiSync Room Slide Operation Manual
What should I do if the slideout room does not move when the switch is pressed?
First, ensure the system is turned on, the battery is fully charged and connected, and transit bars are removed. If it still does not move, you may need to manually override the system.
From: Power Gear Electric Slide-Out System Operations and Service Manual
How do I manually override the slideout system in case of power loss?
Turn off the switch, locate the controller and disconnect the wiring, rotate the brake lever counter-clockwise to release the brake, and then use a wrench or crank handle to move the room.
From: Power Gear Electric Slide-Out System Operations and Service Manual