Key facts
- Manuals
- 1
- Languages
- EN
- Last added
- 2023-11-17
Featured Perlick manuals

Perlick PKHT24 Commercial Glasswasher Installation & Operation Manual
The Perlick PKHT24 is a hot-water sanitizing, single-rack, undercounter commercial glasswasher with a self-contained booster heater. The manual covers receiving, installation, electrical and plumbing requirements, operation, cleaning, maintenance, troubleshooting, parts kits, and electrical diagrams.
It describes a 2-minute operational cycle with a 94-second wash and 16-second rinse. The Safety-Temp feature pauses the timer if the booster heater has not reached 180°F and advances to rinse once that temperature is reached.
Covers: Introduction · Specifications · Operational Cycle · Getting Started · Electrical · Plumbing
Latest Perlick manuals
Perlick PKHT24 Commercial Glasswasher Installation & Operation Manual
User Manual 20 pages · 3.6 MB · ENInstallation and operation manual for the Perlick PKHT24 hot-water sanitizing undercounter commercial glasswasher.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in Perlick manuals
How do I initially fill the PKHT24 each day?
Push the switch marked "FILL"; the machine is full when water begins to flow into the scrap tray.
From: Perlick PKHT24 Commercial Glasswasher Installation & Operation Manual
What water supply is required for the PKHT24?
The supply water must be at least 140°F at 24 psi, with a 6 gpm flow rate and 60 gph recovery rate, through pipe at least 1/2 inch.