Micro crystal Manuals

ManualLib has 2 Micro crystal manuals. Every file can be read online or downloaded as a PDF for free.

Application Note 2

Key facts

Manuals
2
Languages
EN
Last added
2023-10-20

Latest Micro crystal manuals

Which document do I need?

Application Note

How to use the product for one specific task, with worked examples.

Questions answered in Micro crystal manuals

What is the time accuracy of the RV-3032-C7?

The module provides a time accuracy of ±2.5 ppm from -40 to +85°C and ±20 ppm from +85°C to +105°C.

From: RV-3032-C7 DTCXO Temp. Compensated Real-Time Clock Module with I2C-Bus Interface Application Manual

What is the operating voltage range?

The module supports a wide timekeeping voltage range from 1.3 to 5.5 V.

From: RV-3032-C7 DTCXO Temp. Compensated Real-Time Clock Module with I2C-Bus Interface Application Manual

What is the time accuracy of the RV-8803-C7 at standard temperatures?

The time accuracy is ±1.5 ppm from 0 to +50°C.

From: Micro Crystal RV-8803-C7 DTCXO Temp. Compensated Real-Time Clock Module Application Manual

Does the RV-8803-C7 support extended temperature ranges?

Yes, it supports an extended range from +85°C to +105°C with limitations, achieving ±7.0 ppm accuracy.

From: Micro Crystal RV-8803-C7 DTCXO Temp. Compensated Real-Time Clock Module Application Manual