Featured Measurement Computing manuals

Measurement Computing USB-3106 User's Guide
The Measurement Computing USB-3106 is a USB 2.0 full-speed device designed for data acquisition and control. It features 16 channels of analog voltage output, 16 channels of analog current output, eight bidirectional digital I/O connections, and one 32-bit event counter. The device is powered directly by the +5 volt USB supply from the host computer, requiring no external power source.
Covers: Introducing the USB-3106 · Installing the USB-3106 · Functional Details · Specifications · USB specifications · Environmental

Measurement Computing USB-3101 USB-based Analog Output User's Guide
The USB-3101 is a Measurement Computing USB 2.0 full-speed data acquisition device with four channels of analog voltage output, eight digital I/O connections, and one 32-bit event counter. Each DAC channel can be set independently to a bipolar +10 V or unipolar 0 to 10 V range, and analog outputs may be updated individually or simultaneously.
The device is powered by the +5 volt USB supply and requires software installation before hardware installation. The recommended calibration interval is one year, and initial factory calibration is performed by Measurement Computing.
Covers: Preface · Introducing the USB-3101 · Installing the USB-3101 · Functional Details · Specifications · EU Declaration of Conformity
Latest Measurement Computing manuals
Measurement Computing USB-3106 User's Guide
User Manual 26 pages · 963 KB · ENThis guide covers the installation, configuration, and functional details of the Measurement Computing USB-3106 data acquisition board.
Measurement Computing USB-3101 USB-based Analog Output User's Guide
User Manual 19 pages · 977 KB · ENUser's guide for the Measurement Computing USB-3101, a USB data acquisition device with four analog outputs, eight digital I/O lines, and a 32-bit counter.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in Measurement Computing manuals
Does the USB-3106 require external power?
No, the device is powered by the +5 volt USB supply from the computer and no external power is required.
What operating systems are supported?
The USB-3106 is supported under popular Microsoft Windows operating systems.
How many analog voltage output channels does the USB-3101 provide?
Four.
From: Measurement Computing USB-3101 USB-based Analog Output User's Guide
What is the bipolar analog output range?
+10 V.