User Manual

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in LMI manuals

What safety equipment is required when working on the pump?

Always wear protective clothing, face shield, safety glasses, and gloves.

From: LMI Series A Electronic Metering Pumps Instruction Manual

Can the pump be permanently mounted to a building?

No, the pump is cord connected and not intended for permanent mounting to a building.

From: LMI Series A Electronic Metering Pumps Instruction Manual

Does the pump require a battery?

No, the pump uses continuous non-volatile memory (EEPROM) and does not require a battery.

From: LMI B9 and C9 Electronic Metering Pump Instruction Manual

What causes the E1 MININT error message?

The E1 MININT error is caused by a Low-Level fault with a Low-Level Switch connected to the pump.

From: LMI B9 and C9 Electronic Metering Pump Instruction Manual

How often should the head bolts be retightened?

It is recommended to tighten the bolts to 25 inch-pounds after the first week of operation and on a monthly basis thereafter.

From: LMI ROYTRONIC EXCEL Series AD Electronic Metering Pump Instruction Manual

What operating temperature range is allowed for the pump?

The pump operates within a temperature range of 14 to 113°F or -10 to 45°C.

From: LMI ROYTRONIC EXCEL Series AD Electronic Metering Pump Instruction Manual