LMI Series A Electronic Metering Pumps Instruction Manual
This document serves as the instruction manual for LMI Series A Electronic Metering Pumps. It covers essential safety precautions, installation procedures including various mounting options like flooded suction and suction lift, and tubing connections. The guide details the setup of liquid ends, including FastPrime and AutoPrime heads, and four-function valves.
Covers: Precautions · Introduction · Specifications · Unpacking Check List · Installation · Pump Mounting

LMI B9 and C9 Electronic Metering Pump Instruction Manual
This manual provides instructions for the LMI Series B9 and C9 electronic metering pumps, which feature microprocessor control for accurate automation. It details unpacking, installation, and the interpretation of the model number found on the pump's data plate.
The document covers operation of the keypad and display, including speed adjustment, priming, and pressure level control. It also explains external control modes, programming pulse values, and advanced setup menu features such as batch accumulation and computer communication.
Covers: Introduction · Unpacking · Features · How to Interpret the Model Number · Pre-Installation/Installation Instructions · Accessories

LMI ROYTRONIC EXCEL Series AD Electronic Metering Pump Instruction Manual
The document serves as the instruction manual for the LMI ROYTRONIC EXCEL™ Series AD Electronic Metering Pumps. It provides comprehensive guidance on safety precautions, installation procedures including various mounting options and tubing connections, and operation instructions for different control modes such as local, remote, pulse, and analog inputs.
The guide also details routine maintenance tasks like diaphragm replacement, valve servicing, and drive parts lists. Additionally, it includes troubleshooting steps and wiring diagrams to assist with setup and repair of the pump units.
Covers: Precautions · Specifications · Installation · Operation · Output Adjustment Controls · Spare Parts Replacement
Latest LMI manuals
LMI Series A Electronic Metering Pumps Instruction Manual
User Manual 40 pages · 4.9 MB · ENThis manual provides installation, operation, maintenance, and troubleshooting instructions for LMI Series A electronic metering pumps.
LMI B9 and C9 Electronic Metering Pump Instruction Manual
User Manual 36 pages · 617 KB · ENInstruction manual for the LMI Series B9 and C9 electronic metering pumps covering installation, operation, programming, and error messages.
LMI ROYTRONIC EXCEL Series AD Electronic Metering Pump Instruction Manual
User Manual 44 pages · 2.2 MB · ENThis manual covers installation, operation, maintenance, and troubleshooting for LMI ROYTRONIC EXCEL Series AD electronic metering pumps.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in LMI manuals
What safety equipment is required when working on the pump?
Always wear protective clothing, face shield, safety glasses, and gloves.
From: LMI Series A Electronic Metering Pumps Instruction Manual
Can the pump be permanently mounted to a building?
No, the pump is cord connected and not intended for permanent mounting to a building.
From: LMI Series A Electronic Metering Pumps Instruction Manual
Does the pump require a battery?
No, the pump uses continuous non-volatile memory (EEPROM) and does not require a battery.
From: LMI B9 and C9 Electronic Metering Pump Instruction Manual
What causes the E1 MININT error message?
The E1 MININT error is caused by a Low-Level fault with a Low-Level Switch connected to the pump.
From: LMI B9 and C9 Electronic Metering Pump Instruction Manual
How often should the head bolts be retightened?
It is recommended to tighten the bolts to 25 inch-pounds after the first week of operation and on a monthly basis thereafter.
From: LMI ROYTRONIC EXCEL Series AD Electronic Metering Pump Instruction Manual
What operating temperature range is allowed for the pump?
The pump operates within a temperature range of 14 to 113°F or -10 to 45°C.
From: LMI ROYTRONIC EXCEL Series AD Electronic Metering Pump Instruction Manual