Featured Humboldt manuals

Humboldt HM-4150 Falling Head Permeability Distribution Panel Quick Start Guide
The document is a Quick Start Guide for the Humboldt HM-4150 Distribution Panel, a device used for falling head and rising tail permeability testing. It details the initial setup, including determining burette readings and verifying cross-sectional areas. The guide also covers the step-by-step procedure for connecting the triaxial cell, filling the burettes, and stabilizing the system before taking measurements.
Covers: Burette reading determination · Cross-sectional area verification · Triaxial cell connection · Valve operation (Fill/Drain/Vent) · System stabilization · Data recording and calculation

Humboldt H-2085 Flash & Fire Point Tester User Manual
The document serves as a guide for setting up, operating, and maintaining the Humboldt H-2085 Flash & Fire Point Tester. It explicitly states that it does not provide the information required to perform ASTM tests, which must be obtained from the American Society for Testing and Materials (ASTM). The manual includes instructions for using the Powertrol heater included with the unit.
Covers: Introduction · Powertrol Heater Instructions · Storage Procedure · Parts List · Replacement Parts · Wiring Diagrams
Latest Humboldt manuals
Humboldt HM-4150 Falling Head Permeability Distribution Panel Quick Start Guide
User Manual 15 pages · 2.2 MB · ENThis guide provides instructions for setting up and operating the Humboldt HM-4150 Distribution Panel for falling head permeability tests.
Humboldt H-2085 Flash & Fire Point Tester User Manual
User Manual 8 pages · 1.1 MB · ENThis manual covers the setup, operation, and maintenance of the Humboldt H-2085 Flash & Fire Point Tester.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in Humboldt manuals
How do you verify the burette cross-sectional area?
Measure the length of a known volume of the burette using a steel ruler and divide the volume by the length.
From: Humboldt HM-4150 Falling Head Permeability Distribution Panel Quick Start Guide
What is the formula for calculating permeability?
Permeability K is calculated using the areas of the reservoirs, the length of the specimen, the average head loss, and the time interval.
From: Humboldt HM-4150 Falling Head Permeability Distribution Panel Quick Start Guide
What is the Humboldt H-2085 used for?
This instrument is used for setting up, operating, and maintaining a flash and fire point test, though the manual does not supply the specific information required to perform the ASTM test.
From: Humboldt H-2085 Flash & Fire Point Tester User Manual
What are the electrical ratings for the Powertrol heater?
The Powertrol heater is available in two versions: one rated for 115V and another rated for 230V.
From: Humboldt H-2085 Flash & Fire Point Tester User Manual