Alphatron Marine AlphaTurn Rate of Turn Indicator (MED) Installation and Operation Manual
This manual provides step-by-step instructions for installing and operating the AlphaTurn Rate of Turn Indicator (MED), a navigation device for ships. It covers mechanical and electrical installation, software setup, operational settings, and maintenance. Safety warnings and compliance standards are included to ensure proper use and prevent damage or injury. The device is designed for integration with ship’s compass systems and supports NMEA data transmission.
The AlphaTurn is a Type Approved MED system that displays the rate of turn in degrees per minute. It includes hardware specifications, connection diagrams, and configuration options for serial interfaces, Ethernet, and display settings. The manual also includes definitions and abbreviations for navigation and marine electronics terminology.
Covers: Preface · Safety Information · Introduction · Installation Instructions · Operation · Maintenance

Alphatron Marine ALPHAMINICOURSE Gyro Compass Installation and Operation Manual
The Alphatron Marine ALPHAMINICOURSE is a gyro compass designed to determine ship heading relative to the geographic meridian. It operates in both Gyro Compass (GC) mode and Directional Gyro (DG) mode, utilizing external inputs from GPS receivers and speed logs to apply latitude and speed corrections for improved accuracy. The unit consists of a Main Unit containing a high-precision dynamically tuned gyroscope and a Control Unit that displays heading, latitude, speed, and system status.
Covers: Warranty · Introduction · Installation · Prestarting Procedures · Operation · Technical Data

Alphatron Marine BASICTURN Rate of Turn / Swing Meter Installation & User Manual
This manual provides instructions for installing and operating the BASICTURN rate of turn meter, designed for inland shipping. It covers hardware setup, sensor positioning, wiring, grounding, power connection, and commissioning. The device includes an indicator and a single-axis gyro sensor, with optional connections to radar or autopilot systems. It also includes troubleshooting and maintenance guidance.
The BASICTURN is available in three versions (30°/min, 90°/min, 300°/min) and complies with RHINE shipping standards. It features galvanic isolation outputs and an alarm output. Installation must follow specified guidelines to avoid voiding warranty, and service must be performed by certified personnel.
Covers: Revision History · Introduction · Installation · Controlling the BASICTURN · Troubleshooting · Maintenance
Latest Alphatron Marine manuals
Alphatron Marine AlphaTurn Rate of Turn Indicator (MED) Installation and Operation Manual
User Manual 57 pages · 9.8 MB · ENInstallation and operation guide for Alphatron Marine's AlphaTurn Rate of Turn Indicator (MED), covering safety, mounting, wiring, software, and settings.
Alphatron Marine ALPHAMINICOURSE Gyro Compass Installation and Operation Manual
User Manual 68 pages · 2.2 MB · ENThis manual provides installation, operation, and maintenance instructions for the Alphatron Marine ALPHAMINICOURSE Gyro Compass, including alignment…
Alphatron Marine BASICTURN Rate of Turn / Swing Meter Installation & User Manual
User Manual 16 pages · 320 KB · ENInstallation and operation guide for Alphatron Marine's BASICTURN rate of turn meter for inland shipping.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in Alphatron Marine manuals
What is the AlphaTurn used for?
It is an MED Type Approved system for showing the rate of turn (ROT) on a standard ship's compass.
From: Alphatron Marine AlphaTurn Rate of Turn Indicator (MED) Installation and Operation Manual
What voltage does the device require?
It must be operated at 24 VDC to avoid fire, electric shock, or equipment failure.
From: Alphatron Marine AlphaTurn Rate of Turn Indicator (MED) Installation and Operation Manual
What are the acceptable voltage limits for the ALPHAMINICOURSE?
The acceptable voltage range is 21.6 VDC to 31.2 VDC.
From: Alphatron Marine ALPHAMINICOURSE Gyro Compass Installation and Operation Manual
How long does the gyro rotor continue to spin after power-off?
The gyro rotor continues to spin for five minutes after the system is powered off.
From: Alphatron Marine ALPHAMINICOURSE Gyro Compass Installation and Operation Manual
What are the available versions of the BASICTURN?
The BASICTURN is available in three versions: 30°/min for extreme large convoys, 90°/min for larger vessels, and 300°/min for smaller vessels.
From: Alphatron Marine BASICTURN Rate of Turn / Swing Meter Installation & User Manual
How do I switch on the BASICTURN?
Press the 'on/off' button briefly to switch on the BASICTURN. The instrument lighting illuminates and the gyro sensor begins to spin.