TOYOBO SYBR Green Realtime PCR Master Mix Plus QPK-212 User Manual

TOYOBO SYBR Green Realtime PCR Master Mix Plus QPK-212 User Manual

User Manual 13 pages · 263 KB · ZH

The SYBR® Green Realtime PCR Master Mix -Plus‑ (Code No.QPK‑212) is a 2× master mix for real‑time quantitative PCR, containing SYBR Green I, dNTPs, MgCl₂, Taq DNA polymerase, anti‑Taq monoclonal antibody and a passive ROX reference dye. It is designed for research use only and is compatible with a wide range of real‑time PCR instruments.

This manual provides the product composition, a list of additional reagents and equipment required, detailed preparation and cycling instructions for both ABI PRISM® and Roche LightCycler™ platforms, common troubleshooting tips, and references to related TOYOBO products. This manual is written in Chinese.

Read online

TOYOBO QPK-212 specifications

Storage temperature-20°C (protected from light)
Short‑term storage4°C for up to 2 months
Reaction volume (ABI PRISM protocol)50 µl
Primer concentration (ABI PRISM protocol)0.2‑0.6 µM
Primer concentration (LightCycler protocol)0.4‑0.8 µM
Annealing temperature range55‑65 °C
Number of reactions per kit (QPK‑212T)40 reactions (1 mL)
Primer length recommendation20‑30 nucleotides

Source: Toyobo QPK-212T SYBR® Green Realtime PCR Master Mix Instruction Manual

All TOYOBO QPK-212 documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What annealing temperature should be used in the PCR cycles?

Set the annealing temperature between 55 °C and 65 °C, depending on the primer melting temperature.

From: Toyobo QPK-212T SYBR® Green Realtime PCR Master Mix Instruction Manual

What should I do if the solution contacts skin or eyes?

Rinse the affected area with plenty of flowing water; if the eyes are affected, rinse thoroughly for several minutes and seek medical attention if irritation persists.

From: TOYOBO SYBR Green Realtime PCR Master Mix Plus QPK-212 User Manual

How many reactions can be performed with one vial?

One 1 ml vial provides enough master mix for 200 reactions of 50 µL each, or 500 reactions of 20 µL each.