LINEAR Application Note 129 handbook
Update: 29 September, 2023
This document describes the stable temperature performance of the LTC5582 and LTC5583 series RMS detectors, and how to improve measurement accuracy through temperature compensation. These RMS detectors maintain stable performance in a temperature range of -40°C to 85°C, at frequencies up to 10GHz (LTC5582) or 6GHz (LTC5583). By using two external resistors for temperature compensation, the measurement error can be reduced to less than 0.5dB.
Brand: LINEAR
File format: PDF
Size: 96 KB
MD5 Checksum: 835671BF8E6BC68EB5431DCACE40462A
Publication date: 05 June, 2012
Downloads: -