Key facts
- Manuals
- 6
- Models
- 1
- Languages
- EN
- Last added
- 2012-07-05
ZORBAX models by category
Featured ZORBAX manuals

Agilent ZORBAX Eclipse XDB HPLC Columns Product Leaflet
The leaflet introduces the ZORBAX Eclipse XDB column family, highlighting the eXtra Dense Bonding (XDB) technology, double endcapping, and the use of hard‑wall sol‑gel silica that provides excellent peak shape and long column life across a wide pH range.
It also lists detailed column specifications, available bonded phases (C18, C8, Phenyl), particle sizes, dimensions, and ordering part numbers, along with purge and test conditions for performance evaluation.
Covers: Technical Overview · Long Column Life at Intermediate pH · Long Column Life at Low pH · More Selectivity Options (C18, C8, Phenyl) · Rapid Resolution · ZORBAX Eclipse XDB Column Specifications
Latest ZORBAX manuals
Agilent ZORBAX Eclipse XDB HPLC Columns Product Leaflet
Product Leaflet 6 pages · 369 KB · ENThe Agilent ZORBAX Eclipse XDB HPLC Columns leaflet describes column technology, specifications, and ordering information.
Zorbax Eclipse XDB-CN Datasheet
Zorbax SB-CN 4.6 x 150 mm (883975.905) 25 mM phosphate buffer; 1.0 mL/min.; 22°C Effect of Organic Modifier pH on Selectivity
This document discusses the effect of organic modifier and pH on the selectivity of Zorbax SB-CN column. pH control is crucial for providing separation stability for polar organic compounds that are basic or acidic. The short-chain SB-CN column is highly stable under low pH conditions (e.g. pH 2.5).
ZORBAX SB-C8 (3.5 m 5 m) (4.6 x 150 mm) (P/N:863953.906 883975.906)
This document introduces the effect of Zorbax 3.5µm silica and 5µm silica on separation efficiency.
ZORBAX SB-C8 Injection 5 l 35°C Detect. UV (254 nm) Mobile Phase: A: H2O to pH 2.0 with TFA; B: ACN Use of short small-particle columns for fast efficient separations
This document describes the use of short, small-particle columns for fast and efficient separations of herbicide mixtures. By using a 3.5µm particle column, similar efficiency can be achieved in a shorter time compared to columns with 5µm particles and twice the length. Additionally, increasing the flow rate on the 3.5µm, 75 mm column further reduces the run-time, with efficiencies nearly equivalent to those of the 5µm 150 mm column run at a slower flow rate.
ZORBAX SB-C18 (3.0 x 250 mm) (P/N: 880975.302) Mobile Phase: A: 0.01% Acetic Acid in H20 B: Acetonitrile 0.01% Acetic Acid Injection volume 50 l 0.5 mL/min 40°C Detect. UV( 230 270
This document details a method for the high-resolution separation of sulfonylurea pesticides using a Zorbax SB-C18 column.
Questions answered in ZORBAX manuals
What particle sizes are available for Eclipse XDB columns?
Eclipse XDB columns are offered with 5 µm and 3.5 µm particle sizes.
From: Agilent ZORBAX Eclipse XDB HPLC Columns Product Leaflet
How much pressure can the columns tolerate?
The columns are packed at pressures exceeding 8000 psi and can tolerate up to 5000 psi in regular use without loss of efficiency.
From: Agilent ZORBAX Eclipse XDB HPLC Columns Product Leaflet