HAYWARD Manuals

HAYWARD ASL Series C125080X5S C85075XES Manual

Describes the features and characteristics of the ASL filter, including ease of installation, operation and maintenance. The filter uses a new glass reinforced, non-corrosive PermaGlassXL filter tank that will provide years of trouble-free operation.

File format: PDF Size:114 KB

HAYWARD ASL Series C1250 ASL Series C850 Manual

The ASL models C850 and C1250 are high-performance swimming pool filters with a maximum flow rating of 70 gallons per hour. Manufactured from Hayward’s exclusive PermaglassXL™ material, ASL is designed to provide years of trouble-free operation. Plumbing connections should use 1-1/4” or 1-1/2” I.D. flexible plastic pipe or hose joined with insert fittings and stainless steel clamps. Unions should be provided for easy servicing if rigid PVC is used. All plumbing connections on the ASL filter are 1-1/2” N.P.T. Plastic male-end adapters should be used when making connections, with three turns of Teflon tape or plastic pipe sealant applied to the male threads. Ball type valves are recommended. The pool suction plumbing should be connected between the skimmer, pool outlet, and the pump. The pool return (inlet) plumbing should also be connected. The filter is equipped with a drain valve or plug for complete filter draining, and a manual air vent valve is provided for bleeding air. Electrical connections should be made according to local codes. Refer to the pump instruction book for pump information.

File format: PDF Size:118 KB

HAYWARD Microprocessor Contol Timer Manual

This is an owner's manual and instruction sheet for the Hayward microprocessor control/timer. The timer is designed for use with all Flex-48 style aboveground pool pump motors. The integrated timer module allows for four possible timer settings and includes a manual override control. The run duration is set during programming. Important safety instructions are provided, emphasizing the risk of hair or body entrapment and drowning if the product is improperly installed or used. The manual also includes a warning to read and follow all notices and instructions before installation, as failure to do so can result in severe injury, death, or property damage. Additional copies of the instructions can be obtained by calling 1-800-831-7133.

File format: PDF Size:74 KB

HAYWARD PSC 2100 Series Operating Manual

This document describes the features and performance of the Hayward 2100 series pool system control, designed and engineered for today's carefree lifestyle. It provides an easy-to-use master remote control that allows monitoring, setting, and controlling up to 12 functions necessary for total pool system control and pool environment control. The controller is designed with advanced technology to provide convenience for users.

File format: PDF Size:567 KB

HAYWARD PSC 2100 Series Installation Manual

This document provides installation and programming instructions for the HAYWARD® 2100 Series pool system control, and describes its features and performance.

File format: PDF Size:3881 KB

HAYWARD pool Boss Manual

This document is the installation instructions for Hayward R, including water safety instructions, electrical specifications, product specifications, electrical safety instructions, etc.

File format: PDF Size:5077 KB

HAYWARD Super Pump Series owner's MANUAL

The Hayward Super PumpTM is specifically engineered for the demanding requirements of today’s in-ground swimming pool/spa that is equipped with large capacity filters, heaters, and pool cleaning equipment. The Super is a self-priming pump that incorporates an improved seal and impeller design that will provide many years of efficient, dependable, corrosion-free service. The advanced design provides superior performance while reducing maintenance requirements.

File format: PDF Size:564 KB

HAYWARD IS3000XAZ-05 owner's MANUAL

This manual is the instruction manual for the Hayward Super II pump. It introduces the features of the pump and the methods of installation, operation and maintenance.

File format: PDF Size:586 KB

HAYWARD IS4000 owner's MANUAL

The Hayward NorthStar Pump is specifically engineered for today's demanding requirements of in-ground swimming pool/spa that is equipped with large capacity filters, heaters, and pool cleaning equipment. The NorthStar is a self-priming pump that includes an improved seal and impeller design that will provide many years of efficient, dependable, corrosion-free service. The advanced design provides superior performance while reducing maintenance requirements.

File format: PDF Size:424 KB

HAYWARD IS2700 owner's MANUAL

This manual introduces the Hayward Max-Flo II™ pump series, which combines performance, dependability and value with durable corrosion-proof construction. It is designed for pools of all types and sizes.

File format: PDF Size:437 KB

HAYWARD IS2300 Rev-A1 owner's MANUAL

File format: PDF Size:0 KB

HAYWARD IS3400V5PRev-c owner's MANUAL

This document is the user manual for Hayward EcoStar pump SP3400VSP. It introduces the features and characteristics of the pump, including the maximum speed, minimum speed, maximum power, timer, speed, etc.

File format: PDF Size:5702 KB

HAYWARD IS6060 owner's MANUAL

The Hayward 6060 booster pump is specifically engineered for the demanding requirements of today’s in-ground swimming pool cleaning systems. The 6060 booster pump includes an improved seal and impeller design that will provide many years of efficient, dependable, corrosion-free service. The advanced design provides superior performance while reducing maintenance requirements.

File format: PDF Size:429 KB

HAYWARD ISSP1591 owner's MANUAL

This manual introduces the features and characteristics of the Hayward Power-Flo® Matrix™ pump series, including the pump design, installation, operation and maintenance.

File format: PDF Size:794 KB

HAYWARD IS1575X15-00 owner's MANUAL

File format: PDF Size:0 KB

HAYWARD IS1500ST-04 owner's MANUAL

This is an owner's manual and instruction sheet for the Hayward Microprocessor Control/Timer. The timer is designed for use with all 115 volt Flex-48 style aboveground pool pump motors. It is important to closely follow all instructions to ensure safety. The manual includes warnings about electric hazards and the need for qualified personnel to perform electrical connections in compliance with applicable codes. It emphasizes the importance of using a ground fault circuit interrupter (GFCI) and properly grounding the motor. The manual also warns against allowing unsupervised children to use the product and specifies that it is for use with permanently installed pools, hot tubs, and spas. It should not be used with storable pools. The document provides detailed instructions for installation, operation, and maintenance of the timer.

File format: PDF Size:83 KB

HAYWARD FILE E39338 owner's MANUAL

This document is about the safety instructions for Hayward ColorLogic/Crystalogic lighting fixtures. These fixtures are UL certified and can be used with virtually all manufacturer's luminaire housings (forming shell) already installed in the field. This luminaire does not require bonding or grounding when powered by a listed pool/spa transformer and installed per the National Electrical Code.

File format: PDF Size:104 KB

hayward Replacing 120 volt pool or spa lights with Universal ColorLogic or CrystaLogic

This document guides the user on how to replace existing 120V pool or spa lights with Universal ColorLogicTM or CrystaLogicTM, and requires a suitable voltage transformer.

File format: PDF Size:1093 KB

HAYWARD LPCUS11xxx LPCUN11xxx owner's MANUAL

This manual describes the installation and operation of Hayward Universal ColorLogic ® and CrystaLogic TM light fixtures.

File format: PDF Size:2570 KB

HAYWARD SP0604C owner's MANUAL

This manual provides installation instructions for Hayward stainless steel luminaire housings (niches) for swimming pools and spas. These niches come in 4 models for concrete/gunite pool and spas and feature side and rear conduit connections. These niches need to be used with Hayward Astrolite, Astrolite II, or ColorLogic pool and spa lights in order to receive UL approval. Other pool and spa lights can fit into Hayward niches, but the installation will not carry a UL approval.

File format: PDF Size:1952 KB

Brands



Products