Evaluation Data of CERALOCK Oscillation Circuit MURATA Part No.: CSTLS8M00G56-B0 Applied to R5F363AMDFA(Low) Technical Data of Ceramic Resonator Manual
This document provides technical data, test results and performance characteristics of the Murata CSTLS8M00G56-B0 ceramic resonator (CERALOCK® Oscillation Circuit). It includes supply voltage range, temperature range, load capacitance, and measured oscillation frequency for the resonator when used with the R5F363AMDFA(Low) microcontroller.
Key sections cover the resonator specifications, waveform measurements, rise‑time analysis, frequency‑correlation data, and a comparison table of measured parameters such as VIL, VIH, rise time and start‑up voltage. The data help designers verify that the part meets required oscillation and stability criteria.
Covers: Technical Data of Ceramic Resonator · Test Data · Appendix 1: Rise Time · Appendix 2: Frequency Correlation · Comparison Table · Frequency Correlation Data
Latest Evaluation manuals
Evaluation of the Mark-VI Spray Chamber for Flame Atomic Absorption Spectrometry Application Note
The document introduces the performance of Agilent Mark-VI spray chamber, including characteristic concentration, drainage, carbon deposition, burner blockage and interference effects
Evaluation of the Mercury Concentration Accessory for US EPA Methodology Application Note
This document describes the features and application of the Agilent Mercury Concentration Accessory (MCA-90). The accessory allows for the determination of mercury at ultra-low levels and is suitable for environmental monitoring. By utilizing the amalgamation of mercury with gold, the MCA-90 enhances the sensitivity of mercury signals for measurement.
Evaluation Data of CERALOCK Oscillation Circuit MURATA Part No.: CSTLS8M00G56-B0 Applied to R5F363AMDFA(Low) Technical Data of Ceramic Resonator Manual
Datasheet 8 pages · 174 KB · ENEvaluation data and test results for Murata CSTLS8M00G56-B0 ceramic resonator used with R5F363AMDFA(Low) IC.
Which document do I need?
Datasheet
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in Evaluation manuals
What temperature range can the resonator operate in?
It is rated for temperatures between –40 °C and +85 °C.