Featured Camille manuals

Camille Bauer SINEAX Ve11 Temperature Transmitter User Manual
This manual describes the SINEAX Ve11 temperature transmitter, including its features, wiring, and configuration options. It explains how to connect the device to a PC running Windows 95 or later and use the supplied CD for programming and data acquisition.
The document also lists technical specifications such as measurement range, sensor compatibility, output signal, and supply voltage, and provides details on mounting, environmental ratings, and available accessories. This manual is written in Chinese.
Covers: Features · Technical Specifications · Installation and Wiring · Programming and Configuration · Sensor Types · Output Signal
Latest Camille manuals
CAMILLE BAUER 84-2I1-11 84-2I1-12 technology data
SINEAX 2I1 is a passive DC signal isolator designed to isolate load-independent DC current signals. It suppresses noise voltages and currents in a signal loop circuit.
CAMILLE BAUER SINEAX DME 440 with RS 485 interface Programmable multi-transducer
SINEAX DME 440 is a programmable multi-transducer with a RS 485 bus interface (MODBUS®). It supervises several variables of an electrical power system simultaneously and generates 4 proportional analogue output signals. The RS 485 interface enables the user to determine the number of variables to be supervised (up to the maximum available). The levels of all internal energy meters that have been configured (max. 4) can also viewed. Provision is made for programming the SINEAX DME 440 via the bus. A standard EIA 485 interface can be used, but there is no dummy load resistor for the bus. The transducers are also equipped with an RS 232 serial interface to which a PC with the corresponding software can be connected for programming or accessing and executing useful ancillary func- tions. This interface is needed for bus operation to configure the device address, the Baud rate and possibly increasing the telegram waiting time (if the master is too slow) defined in the MODBUS® protocol. The usual methods of connection, the types of measured variables, their ratings, the transfer characteristic for each output and the type of internal energy meter are the main parameters that can be programmed. The ancillary functions include a power system check, provision for displaying the measured values, data storage, system fault diagnosis, serial communication, and external device connection.
Camille Bauer SINEAX Ve11 Temperature Transmitter User Manual
User Manual 7 pages · 122 KB · ZHThe Camille Bauer SINEAX Ve11 manual provides programming, installation, and specifications for the temperature transmitter.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in Camille manuals
What is the output signal range of the SINEAX Ve11?
The device outputs a current signal of 4 to 20 mA.
From: Camille Bauer SINEAX Ve11 Temperature Transmitter User Manual
What supply voltage is required for the transmitter?
The unit requires a DC supply of 12 to 30 V.
From: Camille Bauer SINEAX Ve11 Temperature Transmitter User Manual