Key facts
- Manuals
- 8
- Languages
- ZH
- Last added
- 2012-04-12
Featured RAE manuals
ToxGuard Detector Wireless Gas Detector Operation and Maintenance Manual
The ToxGuard Detector is a wireless intelligent gas detector that can be used as a fixed instrument or a portable device. It offers selectable 2.4 GHz Mesh or 433 MHz wireless modules with line‑of‑sight ranges of up to 100 m or 300 m respectively, low power consumption, long‑life battery, and a large LCD display with audible, visual and vibration alarms.
The manual includes detailed technical specifications, certification information, power and battery details, sensor types, calibration procedures, environmental operating limits, physical dimensions, and safety features such as intrinsic safety design and strong EMI resistance. This manual is written in Chinese.
Covers: Product Overview · Wireless Communication Options · Gas Detection Specifications · Power and Battery · Calibration Procedure · Environmental Ratings
Latest RAE manuals
RAE Systems 7PH3-20 sensor Manual
RAE Systems 7 NO-250 sensor Manual
This document describes the features and characteristics of RAE Systems 7NO-250 sensor, including detection range, maximum detection concentration, sensitivity, baseline current, baseline drift, resolution, response time, linearity, and long-term stability.
RAE Systems 7HCN-30 sensor Manual
RAE Systems 7HCN-30 sensor is a electrochemical sensor produced by RAE Systems with a detection range of 0-30 ppm.
RAE Systems 7HCl sensor Manual
The document provides information about the features and characteristics of the RAE Systems 7HCl sensor, including the normal detection range, maximum detection concentration, sensitivity, baseline current, baseline drift, resolution, response time, linearity, and long-term stability. It also includes information about the operating conditions, physical specifications, and temperature effects of the sensor.
RAE Systems 7HCl-30 sensor Manual
The RAE Systems 7HCl-30 sensor is an electrochemical sensor that can measure 0-30 ppm of hydrogen chloride concentration. Its features include detection range, sensitivity, baseline current, baseline drift, resolution, response time, linearity, long-term stability, working conditions, storage time, storage temperature, service life, warranty period, weight, orientation requirements and dimensions.
RAE Systems 7H2S-50 sensor
The document describes the features and characteristics of the RAE Systems 7H2S-50 sensor, including detection range, sensitivity, resolution, response time, linearity, and long-term stability.
RAE Systems 7ETO-100 sensor Manual
ToxGuard Detector Wireless Gas Detector Operation and Maintenance Manual
Service Manual 1 pages · 165 KB · ZHThe ToxGuard Detector manual provides specifications, wireless options, installation, operation, and maintenance instructions for the gas detector.
Which document do I need?
Service Manual
Disassembly, diagnostics and part numbers, for repair.
Questions answered in RAE manuals
What wireless frequencies does the ToxGuard Detector support?
It can be equipped with either a 2.4 GHz Mesh module or a 433 MHz module for wireless data transmission.
From: ToxGuard Detector Wireless Gas Detector Operation and Maintenance Manual
How long can the battery operate under normal alarm conditions?
The battery can run continuously for more than six months when the alarm is active for about ten minutes per day.
From: ToxGuard Detector Wireless Gas Detector Operation and Maintenance Manual