Siemens SITRANS Probe LU User Manual
The SITRANS Probe LU is a continuous liquid level transmitter designed for process measurement. It supports HART and PROFIBUS PA communication, offers high accuracy, and is available in 6 m and 12 m measurement ranges.
The manual covers mechanical dimensions, material options (ETFE, PVDF), connection sizes, electrical output (4‑20 mA), temperature and pressure limits, and certification details such as ATEX and IEC standards. Installation, wiring, and configuration steps are described for both HART and PROFIBUS PA interfaces. This manual is written in Chinese.
Covers: Product Overview · Technical Specifications · Installation Instructions · Operation Guidelines · Communication Interfaces · Mechanical Details

Siemens SITRANS LVL100 Level Measurement Instrument Manual
The SITRANS LVL100 is a compact vibrating‑fork level switch designed for liquid and slurry measurement in space‑constrained installations. It provides high‑ and low‑level alarms, fault monitoring for corrosion, loss of vibration, or crystal driver breakage, and protects against overflow and pump dry‑run.
The manual includes an overview of the device, technical specifications, installation guidelines, dimension drawings, and ordering information, helping users select the correct configuration and ensure proper integration into process systems. This manual is written in Chinese.
Covers: Overview · Advantages · Applications · Installation · Technical Specifications · Dimensions

SITRANS LU10 Ultrasonic Transmitter Manual
The SITRANS LU10 is a continuous‑measurement ultrasonic transmitter designed for liquid and solid level monitoring in tanks and containers. It can measure up to ten points per unit and is compatible with Dolphin Hus and SmartLinx systems.
The manual covers installation of the optional handheld operator, wiring of the 4‑20 mA output, connection of external temperature sensors, and provides detailed technical data such as measurement range (0.3‑60 m), accuracy (0.1 % of span or 2 mm), power supply (100/115/200‑230 VAC, 50/60 Hz, 15 VA), and environmental ratings (‑50 °C to +150 °C, NEMA 4X). This manual is written in Chinese.
Covers: Features · Applications · Technical Specifications · Measurement Principle · Number of Measurement Points · Output Signal

SITRANS LVL200 Point Type Level Measurement Manual
The SITRANS LVL200 is a compact point‑type level switch designed for liquid and slurry applications in harsh environments, meeting SIL2 requirements. It detects level by monitoring the frequency change of a vibrating crystal when the sensor is covered by the process medium.
The manual covers advantages, application fields, installation guidelines, electrical and process connections, certification information, and detailed technical specifications such as switching delay, operating frequency, voltage ratings, temperature range, and material construction. This manual is written in Chinese.
Covers: Advantages · Applications · Technical Specifications · Selection and Ordering Data · Installation Guidelines · Electrical Connections
Latest SITRANS manuals
Siemens SITRANS Probe LU User Manual
User Manual 5 pages · 1.2 MB · ZHThe Siemens SITRANS Probe LU user manual provides installation, operation, and technical specifications for the continuous liquid level transmitter.
Siemens SITRANS LVL100 Level Measurement Instrument Manual
User Manual 6 pages · 1.4 MB · ZHManual for the Siemens SITRANS LVL100 vibrating fork level switch, covering features, installation, specs and ordering data.
SITRANS LU10 Ultrasonic Transmitter Manual
User Manual 3 pages · 521 KB · ZHThe SITRANS LU10 ultrasonic transmitter manual provides installation, operation, and technical specifications for continuous level measurement.
SITRANS L Level instruments Continuous measurement - Ultrasonic controllers SITRANS LU 01 LU 02 Manual
SITRANS FUE380 ultrasonic flux Meter installation manual
SITRANS L level measurement instrument
SITRANS F M electromagnetic flux Meter Manual
SITRANS LVL200 Point Type Level Measurement Manual
User Manual 16 pages · 1.7 MB · ZHThe SITRANS LVL200 point‑type level measurement manual provides installation, operation, and technical specifications for the device.
SITRANS LVL 200 level measurement instrument Manual
SITRANS T temperature transmitter Manual(1)
SITRANS LU 02 Manual
SITRANS T temperature transmitter Manual
Siemens SITRANS LR 300 Instruction Manual
User Manual 138 pages · 1.5 MB · ZHThe Siemens SITRANS LR 300 Instruction Manual provides safety guidelines, installation steps, communication setup, operation instructions, and technical…
Siemens SITRANS LR260 Level Transmitter User Manual
User Manual 110 pages · 1.9 MB · ZHThe Siemens SITRANS LR260 user manual provides safety guidelines, installation steps, specifications and maintenance instructions for the radar level…
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in SITRANS manuals
Which communication protocols does the Probe LU support?
The Probe LU supports HART and PROFIBUS PA communication interfaces.
What is the measurement range of the Probe LU?
The 6 m version measures from 0.25 m to 6 m, and the 12 m version from 0.25 m to 12 m.
What is the minimum insertion length of the LVL100 fork?
The fork can be inserted as little as 40 mm, making it suitable for tight spaces.
From: Siemens SITRANS LVL100 Level Measurement Instrument Manual
What pressure range can the LVL100 handle?
The device is rated for pressures from –1 to 64 bar g.
From: Siemens SITRANS LVL100 Level Measurement Instrument Manual
What is the measurement range of the ultrasonic sensor?
The ultrasonic sensor measures from 0.3 m up to 60 m.
What output signal does the transmitter use?
It uses a standard 4‑20 mA current loop output.