Ludwig Schneider LW-PS Pressure Transmitter User Manual
This user manual describes the LW-PS pressure transmitter, a piezoresistive device for measuring gauge, absolute, and sealed‑reference pressure. It outlines the product’s design, safety features, specified uses, and technical parameters such as pressure range, accuracy, and output signals.
The document includes detailed sections on dimensions, wiring definitions, cable and plug‑in types, and protection mechanisms like short‑circuit and reverse‑polarity protection. It also lists environmental limits, power supply requirements, and certification information for safe deployment in industrial applications.
Covers: Product Design Function · Overview · Features · Safety · Specified Use · Malfunction

Ludwig Schneider FE10 Intelligent Electromagnetic Flowmeter Instruction Manual
The FE10 is an intelligent electromagnetic flowmeter designed for accurate volumetric flow measurement of conductive media in a wide range of industrial applications. It offers high measurement accuracy, LCD display, and flexible communication options such as HART, MODBUS, GPRS and PROFIBUS.
The manual covers product features, technical specifications, installation guidelines, wiring diagrams for converters, maintenance procedures, troubleshooting steps, and warranty information. Appendices provide detailed guidance on selecting electrode and lining materials for different process fluids.
Covers: Overview · Features · Measurement Principle · Technical Specifications · Installation and Use · Maintenance and Troubleshooting

Ludwig Schneider SP30 Intelligent Pressure Level Transmitter Instruction Manual
The SP30 Intelligent Pressure (Differential Pressure) Level Transmitter from Ludwig Schneider provides accurate liquid level measurement for industrial processes. This manual explains the product’s design, sensor structure, and operating principles.
The document includes sections on product design and markings, installation methods for various transmitter types, commissioning, maintenance procedures, troubleshooting guidance, and safety warnings, helping users set up and operate the transmitter safely and efficiently.
Covers: Product Design and Markings · Introduction · Working Principle · Sensor Structure and Operation · Circuit Board Modules · Technical Specifications

Ludwig Schneider TD70 Rotation Resistance Level Switch Instruction Manual
The Ludwig Schneider TD70 rotation resistance level switch detects material level by using a rotating blade that stops the motor when it contacts the material.
This instruction manual covers product design functions, technical parameters, operating principle, installation precautions, torque adjustment, common faults and their solutions, daily maintenance, unpacking checks, and wiring diagrams.
Covers: Product Design Functions · Technical Parameters · Working Principle · Installation Precautions · Torque Adjustment · Common Faults and Troubleshooting
Latest LUDWIG SCHNEIDER manuals
Ludwig Schneider LW-PS Pressure Transmitter User Manual
User Manual 15 pages · 1.1 MB · ENThe LW-PS pressure transmitter manual provides design, safety, wiring, and technical specifications for proper installation and operation.
Ludwig Schneider FE10 Intelligent Electromagnetic Flowmeter Instruction Manual
Service Manual 39 pages · 1.4 MB · ENThe instruction manual provides design, features, measurement principle, specifications, installation, maintenance and troubleshooting for the Ludwig…
Ludwig Schneider SP30 Intelligent Pressure Level Transmitter Instruction Manual
User Manual 26 pages · 7 MB · ENInstruction manual for the Ludwig Schneider SP30 intelligent pressure (differential pressure) level transmitter, covering design, installation, operation…
Ludwig Schneider TD70 Rotation Resistance Level Switch Instruction Manual
User Manual 5 pages · 601 KB · ENThe instruction manual provides design functions, technical parameters, installation, torque adjustment, troubleshooting, maintenance, and wiring diagrams…
Ludwig Schneider PDG70 26GHz Radar Level Meter User Manual
User Manual 35 pages · 1.4 MB · ZHUser manual for the Ludwig Schneider PDG70 26 GHz radar level meter covering installation, wiring, operation and troubleshooting.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Service Manual
Disassembly, diagnostics and part numbers, for repair.
Questions answered in LUDWIG SCHNEIDER manuals
What is the flow measurement range of the FE10?
The FE10 can measure flow rates from 0.5 to 10 meters per second.
From: Ludwig Schneider FE10 Intelligent Electromagnetic Flowmeter Instruction Manual
How should the sensor be installed in the pipeline?
The sensor can be installed on vertical, horizontal, or inclined pipes, but the center line of the two electrodes must be horizontal.
From: Ludwig Schneider FE10 Intelligent Electromagnetic Flowmeter Instruction Manual
What are common reasons why the blade does not rotate?
The blade may not rotate if the power is not connected properly or if the motor has burnt out; check the wiring and replace the motor if necessary.
From: Ludwig Schneider TD70 Rotation Resistance Level Switch Instruction Manual
How should the wiring box be installed?
The wiring box inlet must face down and the cable‑fixing nut must be tightened; for horizontal installation mount the switch at a 15°–20° downward angle.
From: Ludwig Schneider TD70 Rotation Resistance Level Switch Instruction Manual
What is the maximum measurement distance of the PDG70?
The PDG70 can measure up to 80 meters.
From: Ludwig Schneider PDG70 26GHz Radar Level Meter User Manual