Featured Shenzhen市诺顺 manuals

Rosun RS-3011 Pt100 Isolation Transmitter Manual
The RS-3011 is a Pt100 isolation transmitter designed for industrial temperature monitoring. It measures temperatures from -200 °C to +500 °C, offers 4–20 mA or 0–5 V output signals, and provides 2500 VDC isolation in compliance with DIN35 standards. The device features high accuracy (0.2 % FSR) and supports multiple power supply options (12 V, 15 V, 24 V).\n\nThis manual includes the technical parameters, wiring diagrams, pin assignments, and installation guidelines. It details the electrical characteristics, pin functions for Pt100 inputs, and recommended connection methods, helping users set up and operate the transmitter safely and correctly. This manual is written in Chinese.
Covers: Technical Parameters · Electrical Characteristics · Pin Assignment · Wiring Diagram · Installation Instructions · Performance Specifications

Rousun Technology RS-1112 Isolated Current/Voltage Transmitter Manual
The RS-1112 transmitter converts AC/DC input signals to standardized isolated output signals for power, process control, instrumentation and medical equipment. It supports input current ranges of 0‑1 mA, 0‑10 mA, 0‑20 mA and 4‑20 mA, and offers output options of 4‑20 mA, 0‑20 mA, 0‑5 VDC, 1‑5 VDC and 0‑10 VDC.
Key electrical specifications include 3000 VDC isolation between input and output, accuracy of ≤0.2 %, power supply options of DC 5 V, 12 V or 24 V, operating temperature from –25 °C to +70 °C and humidity 10 %–90 %. The manual provides wiring diagrams, installation steps and calibration procedures. This manual is written in Chinese.
Covers: Product Overview · Technical Specifications · Electrical Characteristics · Wiring Diagram · Installation Instructions · Calibration Procedure

Rosun RS-1114 Passive DC Current Isolation Module Manual
The RS-1114 is a passive direct‑current isolation module that converts 4‑20 mA (or 0‑20 mA) input signals to isolated output signals without requiring an external power supply. It uses a SIP12 package, offers high isolation voltage, low input‑output offset, and compact size, making it suitable for industrial signal isolation and conversion.
The manual includes a description of the module’s pin functions, a reference wiring diagram, technical parameters such as isolation voltage and temperature ranges, and important installation precautions to ensure safe and reliable operation. This manual is written in Chinese.
Covers: Overview · Model Description · Typical Applications · Wiring Diagram · Technical Parameters · Pin Descriptions

Rousun RS-1224 Dual-Channel Non-Contact DC Current Controller User Manual
The RS-1224 is a dual‑channel non‑contact DC current controller designed for 4~20 mA input and output signals. It offers high accuracy (<0.2 %) and operates over a wide temperature range.
This manual details the technical specifications, pin assignments, wiring connections, and performance parameters such as accuracy, temperature limits, and power supply requirements. It also includes a pin‑out table and wiring diagram to aid installation and troubleshooting. This manual is written in Chinese.
Covers: Technical Specifications · Accuracy · Input and Output Signals · Operating Temperature · Power Supply · Pin Assignment
Latest Shenzhen市诺顺 manuals
Rosun RS-3011 Pt100 Isolation Transmitter Manual
User Manual 3 pages · 37 KB · ZHThe Rosun RS-3011 Pt100 isolation transmitter manual provides specifications, wiring diagrams, and installation instructions for temperature measurement…
Rousun Technology RS-1112 Isolated Current/Voltage Transmitter Manual
User Manual 4 pages · 84 KB · ZHThe RS-1112 is a single‑channel isolated current/voltage transmitter with multiple input ranges, several output options, 3000 VDC isolation and high accuracy.
Rosun RS-1114 Passive DC Current Isolation Module Manual
User Manual 2 pages · 107 KB · ZHThe Rosun RS-1114 manual provides an overview, wiring diagram, technical specifications, and usage notes for the passive DC current isolation module.
Rousun RS-1224 Dual-Channel Non-Contact DC Current Controller User Manual
User Manual 3 pages · 38 KB · ZHThe Rousun RS-1224 manual provides specifications, wiring diagram, and operating instructions for the dual‑channel non‑contact DC current controller.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in Shenzhen市诺顺 manuals
What temperature range does the RS-3011 measure?
It measures temperatures from -200 °C to +500 °C.
What output signals are available on the RS-3011?
The transmitter provides either a 4–20 mA current loop or a 0–5 V voltage output.
What input current ranges does the RS-1112 support?
It supports 0‑1 mA, 0‑10 mA, 0‑20 mA and 4‑20 mA input current ranges.
From: Rousun Technology RS-1112 Isolated Current/Voltage Transmitter Manual
What output signals can be selected on the RS-1112?
The device can output 4‑20 mA, 0‑20 mA, 0‑5 VDC, 1‑5 VDC or 0‑10 VDC signals.
From: Rousun Technology RS-1112 Isolated Current/Voltage Transmitter Manual
What is the isolation voltage rating of the RS-1114 module?
The module provides isolation voltage between 1500 VDC and 2500 VDC.
From: Rosun RS-1114 Passive DC Current Isolation Module Manual
What input and output current ranges does the RS-1114 support?
Both the input and output signals can be 4‑20 mA (or 0‑20 mA).
From: Rosun RS-1114 Passive DC Current Isolation Module Manual