Key facts
- Manuals
- 5
- Models
- 1
- Languages
- ZH
- Last added
- 2026-09-29
SL models by category
Featured SL manuals

SL SL3860 IPTG Solution Instruction Manual
The SL3860 IPTG solution is supplied as a sterile, filtered 50 mg/mL solution in 1 mL vials. It should be stored at –20 °C and remains usable for at least 12 months. The product is used as an inducer in recombinant protein expression and as part of blue‑white colony screening.
The manual provides preparation guidelines, including the amount of solution required to reach specific final concentrations (e.g., 0.5 mM in 1 L culture requires 2.38 mL of the 50 mg/mL solution) and instructions for incorporating IPTG and X‑gal into agar plates for screening. This manual is written in Chinese.
Covers: 产品编号 · 保存条件 · 包装内容 · 产品简介 · 使用方法 · 蛋白表达诱导

SL6500 Cell Permeabilization Liquid/PBS‑Triton Product Sheet
SL6500 Cell Permeabilization Liquid/PBS‑Triton is a ready‑to‑use working solution containing Triton X‑100 in PBS. It is designed for strong permeabilization of cell, frozen, or paraffin sections during various in‑situ detection methods such as immunofluorescence, immunohistochemistry, immunocytochemistry, and flow cytometry.
The solution can be applied directly without dilution. Typical use is 50‑100 µL per tissue section or 1 mL per well of a six‑well plate, fully covering the sample. Incubate at room temperature for 5‑10 minutes (10‑30 minutes for difficult samples). Store at 4 °C; the product remains stable for one year. This manual is written in Chinese.
Covers: Product Content · Product Description · Usage Instructions · Storage and Shelf Life · Precautions

SL Series Automatic Mechanical Watch User Manual
This manual explains how to operate the SL Series automatic mechanical watch, including setting the time, adjusting the date, and using the crown for winding. It also covers special functions such as the perpetual calendar, luminous mode, and water‑resistance guidelines.
Maintenance advice is provided, such as regular manual winding when the watch is not worn, avoiding strong magnetic fields, and proper care to preserve accuracy and power reserve. This manual is written in Chinese.
Covers: Time Setting · Date Setting · Manual Winding · Automatic Winding · Power Reserve Indicator · Perpetual Calendar
Latest SL manuals
SL SL3860 IPTG Solution Instruction Manual
Product Leaflet 1 pages · 95 KB · ZHInstructions for storage, handling, and use of SL3860 IPTG solution for protein expression and blue‑white screening.
SL6500 Cell Permeabilization Liquid/PBS‑Triton Product Sheet
Product Leaflet 2 pages · 102 KB · ZHThe SL6500 Cell Permeabilization Liquid/PBS‑Triton is a ready‑to‑use solution for permeabilizing cells in immunostaining, stored at 4 °C for one year.
SL Series Automatic Mechanical Watch User Manual
User Manual 1 pages · 643 KB · ZHThe SL Series automatic mechanical watch user manual provides instructions for time and date setting, winding, water resistance, and maintenance.
SL CONDOR CONDOR Global Performance Switchers GPC41 SERIES 41W COMMERCIAL SWITCHERS Manual(1)
SL CONDOR CONDOR Global Performance Switchers GPC41 SERIES 41W COMMERCIAL SWITCHERS Manual(1)(1)
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in SL manuals
What is the recommended storage condition?
Store the IPTG solution at –20 °C.
How long is the product valid after manufacture?
The solution remains valid for at least 12 months.
How should the SL6500 solution be stored?
Store the solution at 4 °C; it remains stable for one year.
From: SL6500 Cell Permeabilization Liquid/PBS‑Triton Product Sheet
Does the SL6500 solution need to be diluted before use?
No, it is a ready‑to‑use working liquid and can be applied directly.
From: SL6500 Cell Permeabilization Liquid/PBS‑Triton Product Sheet
How do I set the time on the watch?
Pull the crown out to the second (two‑step) position, turn it clockwise to move the hands to the correct time, then push the crown back in.
How do I set the date?
Pull the crown out to the first position, turn it clockwise or counter‑clockwise to adjust the date, then push the crown back in.
