ProMinent CONCEPT C-type Electromagnetic Metering Pump User Manual
This manual provides safety instructions, installation steps, technical specifications, and troubleshooting for the CONCEPT C‑type electromagnetic metering pump. It is intended for trained personnel who will operate, maintain, or service the pump.
The document covers proper power connection, pump orientation, hose selection, cleaning procedures, and required protective equipment. Compliance information and a product certification page are included at the end. This manual is written in Chinese.
Covers: Safety Instructions · Product Overview · Technical Parameters · Product Identification Code · Performance Data · Installation Dimensions

ProMinent CONCEPT plus Series Metering Pump User Manual
This manual provides comprehensive guidance for the ProMinent CONCEPT plus series metering pump. It includes safety warnings, installation steps, cable and electrical connections, and details on seal materials and control options.
The document also outlines proper operating procedures, fault indicators, and maintenance requirements, ensuring safe and reliable pump performance in industrial applications. This manual is written in Chinese.
Covers: Safety Information · Safety Precautions · Assembly and Installation · Electrical Connection · Cable Options · Seal Material Options
Latest Prominent manuals
ProMinent CONCEPT C-type Electromagnetic Metering Pump User Manual
User Manual 16 pages · 9.2 MB · ZHOperation and safety guide for the ProMinent CONCEPT C‑type electromagnetic metering pump.
ProMinent CONCEPT plus Series Metering Pump User Manual
User Manual 20 pages · 6.8 MB · ZHUser manual for ProMinent CONCEPT plus series metering pump, covering safety, installation, operation, and specifications.
Prominent Operating Instructions Solenoid metering pump delta with controlled solenoid drive optoDrive
This document introduces the operating instructions of the electromagnetic metering pump delta ® , including product features, usage methods and maintenance and maintenance.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in Prominent manuals
Can the pump be run without liquid inside?
No. Running the pump empty can cause internal friction heating and damage, so the pump must never be operated without liquid.
From: ProMinent CONCEPT C-type Electromagnetic Metering Pump User Manual
How should water be removed before first use if the process fluid is not compatible with water?
Rotate the pump head to 180°, drain any residual water, then flush the pump with the intended fluid before starting operation.
From: ProMinent CONCEPT C-type Electromagnetic Metering Pump User Manual
How should the pump be connected to the power supply?
Connect the pump to an AC100‑230 V, 50/60 Hz single‑phase source using the supplied 2 m power cord with a European plug.