Affymetrix GeneChip Mapping Assay 701441 Rev. 2 User Manual
This manual provides step‑by‑step procedures for conducting GeneChip® Mapping experiments, covering sample preparation, restriction digestion, ligation, PCR, fragmentation, labeling, hybridization, washing, staining, and scanning. It also includes a scientific overview of the assay principle and guidance on laboratory setup to avoid contamination.
Additional sections describe weekly and monthly fluidics‑station maintenance, data‑analysis workflows, a comprehensive troubleshooting guide, technical support contacts, and a complete list of required reagents, instruments, and supplier information.
Covers: Scientific Overview · Laboratory Setup · Genomic DNA Preparation · GeneChip Mapping Assay Protocol · Fluidics Station Maintenance · Data Analysis

Affymetrix GeneChip System 3000Dx v.2 Quick Reference Guide
The guide provides step‑by‑step instructions for creating, registering, and cancelling test requests using the system's workflow pane. It explains how to scan specimen IDs, select assay names, and submit requests to the Active Worklist.
It also details the operation of the Hybridization Oven, Fluidics workstation, AutoLoaderDx, and Scanner, including station setup, start/stop procedures, and manual scanning instructions. Safety warnings and status indicators are described throughout.
Covers: Workflow Overview · Creating Test Requests · Cancelling Test Requests · Registration Worklist · Hybridization Oven Operation · Fluidics Workstation Setup

Affymetrix PrimeView™ Human Gene Expression Array Product Data Sheet
The PrimeView™ Human Gene Expression Array is a cartridge‑format microarray designed for use with the GeneChip® Scanner 3000 7G series. It contains 49,395 probe sets, covering 48,658 RefSeq probe sets, 419 UniGene probe sets not covered by RefSeq, and 318 other control probe sets. The array emphasizes well‑annotated genes and uses a perfect‑match‑only design.
Performance data show a median coefficient of variation below 10 % and Pearson correlation coefficients greater than 0.990 for replicate hybridizations. The array is supported by Affymetrix premium reagents and software, and ordering information is provided for 10‑array and 30‑array kits.
Covers: Design and coverage · Performance · Specifications · Ordering information · Related products · Legal and contact information
Latest Affymetrix manuals
Affymetrix GeneChip Mapping Assay 701441 Rev. 2 User Manual
User Manual 160 pages · 1.4 MB · ENDetailed protocols, equipment lists, maintenance steps, and troubleshooting for the Affymetrix GeneChip Mapping Assay (Rev. 2).
Affymetrix GeneChip System 3000Dx v.2 Quick Reference Guide
Quick Start Guide 2 pages · 231 KB · ENQuick reference guide for operating the Affymetrix GeneChip System 3000Dx v.2, covering workflow, test request handling, and instrument setup.
Affymetrix PrimeView™ Human Gene Expression Array Product Data Sheet
Product Leaflet 4 pages · 657 KB · ENThe Affymetrix PrimeView™ Human Gene Expression Array provides whole‑genome coverage with high specificity and reproducibility for 3’ expression analysis.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Quick Start Guide
The shortest path to a working setup, usually only a few pages.
Questions answered in Affymetrix manuals
How do I cancel a test request?
Select the test request you want to cancel, then click the Cancel Test Request button.
From: Affymetrix GeneChip System 3000Dx v.2 Quick Reference Guide
Where can I find the Hybridization Oven setup information?
Refer to the Hybridization Oven 645 quick reference card, part number 08-0255 or 08-0256, for detailed setup instructions.
From: Affymetrix GeneChip System 3000Dx v.2 Quick Reference Guide
What amount of RNA is required for the PrimeView™ array?
The array requires 50–500 ng of input RNA.
From: Affymetrix PrimeView™ Human Gene Expression Array Product Data Sheet
What is the sensitivity of the PrimeView™ Human Gene Expression Array?
The array can detect targets at a sensitivity of at least 1 : 100,000.