Sloan 139ESS Manuals

ManualLib has 2 documents for the Sloan 139ESS: 2 user manuals. Every file can be read online or downloaded as a PDF for free.

User Manual 2

Key facts

Brand
Sloan
Model
139ESS
Documents
2
Languages
ZH
Last added
2012-03-15

Start here

Sloan Royal 139 ESS WB Rinse Valve Manual

Sloan Royal 139 ESS WB Rinse Valve Manual

User Manual 1 pages · 783 KB · ZH

The Royal 139 ESS WB is a concealed‑type sensor flush valve designed for wall‑mounted installation with a stainless‑steel panel. It offers selectable flush volumes of 6.0 L, 9 L, or 13 L and features low‑noise operation, a membrane structure, dual‑filter system, and an infrared adaptive sensor.

Key features include a 3‑second delay before flushing, a 2‑inch (51 mm) wall opening, a 9"×11.6" (238 mm×298 mm) stainless‑steel panel, and compliance with ASTM, ASSE, ANSI/ASME, ADA, and other standards. The valve incorporates a PERMEXTY synthetic rubber membrane, an OPTIMAS EL‑1500‑L infrared sensor, and a trigger‑type solenoid for precise, water‑saving flush control. This manual is written in Chinese.

Read online

Sloan 139ESS specifications

Flush volume6.0 L, 9 L, 13 L
Stainless steel panel size9"×11.6" (238 mm×298 mm)
Flush delay3 seconds
Sensor modelOPTIMAS EL‑1500‑L infrared adaptive sensor
TransformerEL‑342 CN, 240 VAC/24 VAC, 50 VA

Source: Sloan Royal 139 ESS WB Rinse Valve Manual

All Sloan 139ESS documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What flush volumes are available for the Royal 139 ESS WB?

The valve can be configured for 6.0 L, 9 L, or 13 L flush volumes.

From: Sloan Royal 139 ESS WB Rinse Valve Manual

How long is the delay before the valve flushes?

The flush delay is set to 3 seconds.

From: Sloan Royal 139 ESS WB Rinse Valve Manual