TRANBALL QR3613B User Manual

The TRANBALL QR3613B user manual details communication interfaces, technical specs, wiring, and configuration commands for temperature and humidity monitoring.


TRANBALL QR3613B User Manual - cover page
Brand
TRANBALL
Category
Industrial Supply
Document type
User Manual
Language
Chinese
Pages
17
File format
PDF
File size
2.3 MB
Published
28 September, 2026
Updated
28 September, 2026
MD5 checksum
18C22E7F7FE72757A36BF68F2A9D3F1C

About this manual

This manual introduces the QR3613B sensor, which uses an industrial‑standard RS485 MODBUS‑RTU interface and supports multiple output options such as RS232, CAN, 4‑20 mA, ZigBee, LoRa, Wi‑Fi, GPRS and NB‑IoT. It is designed for monitoring temperature, humidity and other status variables with high‑precision internal sensors.

The document provides detailed wiring diagrams, application examples, and step‑by‑step instructions for reading and modifying device parameters (address, baud rate, calibration values) via MODBUS commands. Example command frames and response formats are included for easy integration with PLCs, DCS, or other control systems. This manual is written in Chinese.

What's inside

  • Technical Parameters
  • Product Wiring
  • Application Solutions
  • RS485 Communication Protocol
  • Inquiry Frame (Hex)
  • Read/Modify Device Address
  • Read/Modify Baud Rate
  • Read/Modify Calibration Value
  • Disclaimer

Specifications

Communication InterfaceRS485
Default Baud Rate115200
Power SupplyDC5~24V 1A
Display1.8 inch TFT color screen
Storage Capacity8 M
Maximum Records65000
Operating Temperature-40 °C to 80 °C
Operating Humidity5 %RH to 90 %RH

Frequently asked questions

How can I read the device address?

Send the MODBUS query frame FA 03 00 66 00 01 71 9E; the device will respond with its current address.

How do I change the device's baud rate?

Use the command 01 06 00 67 00 05 F8 16 to set the baud rate code to 5, which changes it to 38400 bps.

How do I adjust the calibration value for temperature?

Send 01 06 00 6B 00 64 F9 FD to increase the calibration offset by 100 units; the device will confirm the change.

Download PDF (2.3 MB)