Key facts
- Manuals
- 3
- Languages
- ZH
- Last added
- 2011-12-19
Featured 陕西帅克传感仪器制造 manuals

Shanxi Shuaike C23 / C800 Analog Pressure Transmitter User Manual
The C23 and C800 series are analog pressure transmitters that use signal‑amplification technology and offer high immunity to electromagnetic interference. They cover a wide range of pressure types—including positive, negative, differential, absolute and gauge pressures—and provide multiple output signal options.
This manual details the performance parameters, electrical and physical specifications, wiring diagrams, installation notes, calibration procedures, and selection guidelines for different application sub‑types. It also includes information on environmental limits, IP ratings, and recommended power supplies. This manual is written in Chinese.
Covers: Performance Parameters · Electrical Parameters · Physical Parameters · Environmental Parameters · Electrical Connection Diagram · Dimensions

Shanxi Shuaike Sensor SC66/SC69/SC65 Slurry Density Meter User Manual
The SC66/SC69/SC65 series are online slurry density meters designed for a wide range of industrial fluids. They feature a twin‑sensor design that provides self‑compensation, zero‑drift elimination, fast response, and high accuracy across various pressure and temperature conditions.
The manual provides detailed performance parameters, electrical connection diagrams, installation guidelines, and selection tables for different process requirements, including explosion‑proof options and multiple output configurations. This manual is written in Chinese.
Covers: Overview · Performance Parameters · Physical Dimensions and Installation · Electrical Connections · Product Selection · Power Supply Options
Latest 陕西帅克传感仪器制造 manuals
Shanxi Shuaike C23 / C800 Analog Pressure Transmitter User Manual
User Manual 4 pages · 333 KB · ZHThe user manual for Shanxi Shuaike C23 and C800 analog pressure transmitters provides specifications, wiring, calibration and installation guidance.
S C 3 2 S C 3 2 L S C 3 2 0 Manual
Shanxi Shuaike Sensor SC66/SC69/SC65 Slurry Density Meter User Manual
User Manual 8 pages · 710 KB · ZHUser manual for Shanxi Shuaike Sensor SC66/SC69/SC65 slurry density meters covering specifications, installation, and operation.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in 陕西帅克传感仪器制造 manuals
What output signal options are available for the C23/C800 transmitters?
The transmitters can output 4–20 mA, 0.5–4.5 V, 1–5 V, 0–5 V, 0–10 V or 0–20 mA depending on the selected configuration.
From: Shanxi Shuaike C23 / C800 Analog Pressure Transmitter User Manual
What is the vibration resistance of the C23 series?
The C23 series can withstand vibration up to 15 g.
From: Shanxi Shuaike C23 / C800 Analog Pressure Transmitter User Manual
What communication ports are available for the SC66/SC69/SC65 meters?
The devices support RS485, RS232, and TTL interfaces; RS485 is required for the explosion‑proof SC66 model.
From: Shanxi Shuaike Sensor SC66/SC69/SC65 Slurry Density Meter User Manual
What supply voltage options can be selected?
Supply voltage can be 9 VDC, 15 VDC, or 24 VDC depending on the model and configuration.
From: Shanxi Shuaike Sensor SC66/SC69/SC65 Slurry Density Meter User Manual