YTC YTC8106 Series Voltage Divider User Manual
The YTC8106 series voltage divider is a high‑voltage measurement device for pulse, lightning and power‑frequency voltages. It features a compact size, light weight, high linearity and true‑RMS measurement capability.
The manual provides technical parameters, step‑by‑step usage instructions, safety distances, maintenance tips and a list of accessories included with the instrument. This manual is written in Chinese.
Covers: Overview · Technical Specifications · Operation Method · Precautions · Instrument Completeness · Model Specifications

YTC YTC2088 Multifunction Power Meter Field Test Instrument User Manual
The YTC2088 is a high‑precision, multifunction field test instrument for power meters, developed by Hubei Yitiancheng Power Equipment Co., Ltd. It integrates voltage and current measurement, meter verification, and wiring judgment in a single portable device with a large LCD display and full‑touch keyboard.
The manual provides detailed functional descriptions, technical specifications, physical layout, step‑by‑step operating procedures, common fault analysis, safety precautions, and several appendices with wiring diagrams and standards references. This manual is written in Chinese.
Covers: Features · Technical Specifications · Physical Appearance · Operation Instructions · Troubleshooting · Precautions

YTC YT-700S Three-way Electromagnetic Valve User Manual
The YT-700S is an explosion‑proof three‑way electromagnetic valve designed for use with AC or DC control signals. The manual introduces the valve’s features, such as a rotatable 265° cable connector, manual switch for testing without power, and a corrosion‑resistant sprayed coating.
It includes detailed specifications, wiring diagrams, installation steps, operation of the manual switch, dimensions, safety precautions for explosive atmospheres, maintenance procedures, troubleshooting tips, and warranty information. This manual is written in Chinese.
Covers: Product Introduction · Technical Parameters · Main Components and Structure Diagram · Manual Switch Operation · Dimensions and Installation · Wiring Instructions
Latest YTC manuals
YTC YTC8106 Series Voltage Divider User Manual
User Manual 7 pages · 268 KB · ZHUser manual for the YTC8106 series AC/DC voltage divider, covering specifications, operation steps and safety precautions.
YTC YTC2088 Multifunction Power Meter Field Test Instrument User Manual
User Manual 38 pages · 680 KB · ZHUser manual for the YTC2088 multifunction power‑meter field test instrument, covering features, specifications, operation, and troubleshooting.
YTC YT-700S Three-way Electromagnetic Valve User Manual
User Manual 8 pages · 590 KB · ZHThe YTC YT-700S three-way electromagnetic valve user manual provides product overview, specifications, installation, wiring, operation, safety and…
YTC intelligence valve Fixed Position Implement YT-2400 series Manual
YTC YT-1200 series Pneumatic valve Fixed Position Implement Manual
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in YTC manuals
How do I select the measurement range for voltages below or above 20 kV?
Select the “LOW” range for voltages under 20 kV and the “HIGH” range for voltages above 20 kV to obtain higher accuracy.
What safety distance should be kept around the divider during use?
Maintain at least a 5‑6 m clearance; larger voltage models require longer distances (e.g., 2 m for <100 kV, 3 m for 150‑200 kV, 4 m for 300 kV).
How many wiring configurations can the instrument automatically judge in three‑phase three‑wire mode?
The instrument can automatically judge 48 different wiring configurations.
From: YTC YTC2088 Multifunction Power Meter Field Test Instrument User Manual
What is the maximum number of calibration results the instrument can store?
It can store up to 100 groups of field calibration results.
From: YTC YTC2088 Multifunction Power Meter Field Test Instrument User Manual
What is the explosion‑proof rating of the YT‑700S valve?
The valve is rated Ex d IIC T6 for explosion‑proof protection.
From: YTC YT-700S Three-way Electromagnetic Valve User Manual
How is the manual switch operated?
The manual switch can be rotated by hand or a flat‑head screwdriver; it is set to the automatic position at the factory and must be turned to manual to stop flow.
From: YTC YT-700S Three-way Electromagnetic Valve User Manual