Key facts
- Manuals
- 7
- Models
- 1
- Languages
- EN · ZH
- Last added
- 2012-02-27
SNB models by category
Featured SNB manuals

Sonbest SLET1000-H Temperature Data Acquisition Workstation Operating Manual
The SLET1000-H is a temperature data acquisition workstation that can connect up to ten humidity sensors via RS232, RS485, CAN or Ethernet. It supports 10 channels, each capable of handling 12‑24 measurement points, and offers secondary development of communication protocols.
The manual covers wiring, power requirements, communication interfaces, sensor bus details, and ordering information, helping users install and operate the device safely and efficiently.
Covers: Overview · Technical Parameters · Features · Wiring · Communication Port · Sensor Interface

SOOBUU SLET1000-H Data Acquisition Workstation Operation Manual
The SLET1000-H is a data acquisition workstation designed for temperature and humidity monitoring. It can connect 120‑240 digital humidity sensors via a bus system and communicates with a host PC using RS232, RS485, CAN or Ethernet.
The manual lists technical parameters such as a measuring range of -55 °C to +125 °C, 0.1 °C resolution, and a power supply of DC 5 V 1 A. It also describes wiring diagrams, power requirements, communication ports, sensor interface wiring, and ordering options for different sensor counts. This manual is written in Chinese.
Covers: Overview · Technical Specifications · Features · Wiring · Power Supply · Communication Port

SNB SLET1000-S DS18B20 date collect Workstation Manual
The SLET1000‑S is a remote digital temperature‑data acquisition system that can connect up to 120‑240 DS18B20 sensors via a bus‑type wiring scheme. It communicates with a host PC through RS232 and optionally CAN, RS485 or Ethernet, providing real‑time temperature readings.
The manual covers the device’s features, technical parameters, wiring instructions, command set for reading and configuring sensors, and a bill of materials. It also describes how to expand the sensor bus, power requirements, and troubleshooting of communication errors. This manual is written in Chinese.
Covers: Overview · Features · Technical Specifications · Communication Protocol · Wiring and Power Supply · Bill of Materials

Sonbest SLI1 Single Bus Intelligent Temperature Data Logging Device Operating Manual
The SLI1 series is a single‑bus intelligent temperature data‑logging device that uses Dallas 1‑Wire technology and supports DS18B20 sensors. It is designed for real‑time temperature monitoring in applications such as industrial plants, cold storage, pharmaceutical GMP, and telecommunications rooms. The device can connect up to 24 sensors on a bus up to 200 m long and offers RS232, optional CAN and RS485 communication ports.
The manual describes hardware connections, power requirements, interface pin definitions, and the user interface with four keys for setting passwords, selecting channels, and configuring alarm limits. It also covers wireless/GPRS extensions, sensor test procedures, and a selection guide for different channel configurations.
Covers: Introduction · Technical Parameters · Typical Program · Interface and Pin Definitions · Power and Communication Ports · Sensor Test Interface
Latest SNB manuals
Sonbest SLET1000-H Temperature Data Acquisition Workstation Operating Manual
User Manual 3 pages · 173 KB · ENThe Sonbest SLET1000-H Operating Manual provides setup, wiring, and specifications for the temperature data acquisition workstation.
SOOBUU SLET1000-H Data Acquisition Workstation Operation Manual
User Manual 3 pages · 156 KB · ZHThe SOOBUU SLET1000-H manual provides specifications, wiring, and operation instructions for temperature and humidity data acquisition.
SNB SLET1000-S DS18B20 date collect Workstation Manual
User Manual 7 pages · 199 KB · ZHThe Soobuu SLET1000‑S manual explains setup, wiring, communication protocol and specifications for the DS18B20 temperature data acquisition server.
Sonbest SLI1 Single Bus Intelligent Temperature Data Logging Device Operating Manual
User Manual 9 pages · 464 KB · ENThe Sonbest SLI1 operating manual provides setup, wiring, sensor configuration, and alarm settings for the single‑bus intelligent temperature data logger.
SNB SLIT3-1 Single Total Line intelligence temperature Inspection Instrument Manual
Sonbest SLET3000 Scene Data Collection Server Operation Manual
User Manual 7 pages · 659 KB · ZHThe Sonbest SLET3000 operation manual describes its CAN/RS485 interfaces, node capacity, power specs and installation details.
Sonbest SLST1-14 Air-Plug Temperature Sensor User Manual
User Manual 4 pages · 276 KB · ENThe Sonbest SLST1-14 air-plug temperature sensor manual provides specifications, wiring details, and application guidance.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in SNB manuals
How many sensor channels does the SLET1000-H support?
The SLET1000-H supports 10 channels, each capable of connecting up to 12‑24 measurement points.
From: Sonbest SLET1000-H Temperature Data Acquisition Workstation Operating Manual
What communication interfaces are available on the SLET1000-H?
It provides a standard RS232 interface and optional CAN, RS485, or Ethernet connections.
From: Sonbest SLET1000-H Temperature Data Acquisition Workstation Operating Manual
How many humidity sensors can the SLET1000-H support?
It can connect 120 to 240 digital humidity sensors, depending on the model configuration.
From: SOOBUU SLET1000-H Data Acquisition Workstation Operation Manual
What communication interfaces are available?
The standard interface is RS232, with optional CAN, RS485, or Ethernet adapters.
From: SOOBUU SLET1000-H Data Acquisition Workstation Operation Manual
How many DS18B20 temperature sensors can the SLET1000‑S connect?
It can connect 120‑240 DS18B20 sensors, distributed over 10 channels with up to 12‑24 sensors per channel.
From: SNB SLET1000-S DS18B20 date collect Workstation Manual
What communication interfaces are supported by the SLET1000‑S?
The standard interface is RS232, and optional CAN, RS485 or Ethernet modules can be added for longer distances.
From: SNB SLET1000-S DS18B20 date collect Workstation Manual
