Featured LD-III称重开关 manuals

Feikang LD-III Weight Switch User Manual
The LD-III weight switch is designed to measure elevator load and provides three load signals – light, full and overload – as a common‑cathode switch output. It consists of a controller, a DS11-3 load sensor and a permanent‑magnet steel piece, featuring a non‑contact sensor and simple, flexible installation.
The manual describes how to install the switch at the bottom centre of the car, the required sensor‑magnet spacing, wiring connections for power and load signals, and adjustment procedures using the three trim resistors. Technical parameters such as supply voltage, drive current and dimensions are also listed. This manual is written in Chinese.
Covers: Introduction · Features and Characteristics · Application Range · Installation · Technical Parameters · Wiring
Latest LD-III称重开关 manuals
Feikang LD-III Weight Switch User Manual
User Manual 3 pages · 276 KB · ZHThe Feikang LD-III weight switch manual provides installation, wiring, adjustment and technical specifications for elevator load measurement.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in LD-III称重开关 manuals
What are the wiring connections for the LD-III weight switch?
Connect red to V+ (DC12‑24V positive), black to V‑ (DC12‑24V negative), yellow to the overload output, and the remaining terminals to the light‑load, full‑load and empty‑load outputs respectively.